background image

 

  

 

 

   

 

Ordercode: 51315  

Galactic Beam G40 

 

Always check and position the laser before anybody enters the room, when the laser is facing an 
area with people 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to 
cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of the reach of children. Never leave the unit running 
unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The operation of a class 3B laser show laser is only allowed if the show is controlled by a skilled and 
well-trained operator familiar with the data included in this manual. 

 

The user is responsible for correct positioning and operating of the Galactic Beam G40. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation of 
this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

The laser will only work between 15-35ºC. 

 

After 3 hours working, you must shut off the laser and let the laser diode cool off for 30 minutes, 
otherwise the laser could be damaged and the warranty becomes void. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 1 meter. 

 

The maximum ambient temperature ta = 35°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 30° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others! 

 

 

Содержание GALACTIC BEAM G40 V1

Страница 1: ...Galactic Beam G40 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 51315 MANUAL ENGLISH...

Страница 2: ...Multiple Galactics Master Slave control 12 Multiple Galactics DMX Control 13 Fixture Linking 14 Data Cabling 14 Control Panel 15 Control Mode 15 DMX Addressing 15 Menu Overview 16 Main Menu Options 1...

Страница 3: ...dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the...

Страница 4: ...into the sky Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury Do not insert objects into air vents...

Страница 5: ...lled out of the reach of children Never leave the unit running unattended Never attempt to bypass the thermostatic switch or fuses For replacement use fuses of same type and rating only The operation...

Страница 6: ...nce total light 160 degrees The legal requirements for using laser entertainment products vary from country to country The user is responsible for the legal requirements at the location country of use...

Страница 7: ...ing or high joists professional trussing systems have to be used Use a clamp to mount the Galactic with the mounting bracket to the trussing system The Galactic must never be fixed swinging freely in...

Страница 8: ...ays a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief de...

Страница 9: ...Power Consumption 12 Watt Beam Diameter 18mm at aperture Laser Class 3B Laser Modulation TTL Laser Safety EN IEC 60825 1 Ed 2 2007 03 Laser Color Green Laser Power 40mW 532nm Green Scan Angle 80 Contr...

Страница 10: ...Fuse 1 A 250V 03 IEC Powerconnector 04 Lock On Off 05 3 pin DMX signal connector OUT 06 3 pin DMX signal connector IN 07 Remote Control 08 LCD Display Menu Buttons 09 Cooling Fan 10 Built in Micropho...

Страница 11: ...Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not s...

Страница 12: ...e included in the box The interlock is the included in the box successor for the optional remote interlock 51316 They should be kept with the Galactic laser The following safety precautions should be...

Страница 13: ...r supply socket 04 When the Galactic is not connected by a DMX cable it functions as a stand alone device 05 Please see page 17 18 for more information about the about the sound control options Multip...

Страница 14: ...gure 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 06 Supply electric power Plug elect...

Страница 15: ...udio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and ar...

Страница 16: ...17 017 etc Please be sure that you don t have any overlapping channels in order to control each Galactic correctly If two or more Galactics are addressed similarly they will work similarly Controlling...

Страница 17: ...16 Ordercode 51315 Galactic Beam G40 Menu Overview...

Страница 18: ...UNC button until the display shows 02 Use the Up Down buttons to scroll through the entire menu Automatic Show with Patterns and Solid Beams Sound Activated Show with Patterns and Solid Beams 03 Use t...

Страница 19: ...utton to store your setting 7 Slave Mode 01 Press the FUNC button until the display shows 02 You can use the same functions on the master device as described on page 12 This means you can set your des...

Страница 20: ...fast 210 255 Zoom In and Out from slow to fast Channel 4 Y axis Rolling 0 127 0 359 degree fixed Y Axis rolling 128 191 Clockwise rolling from slow to fast 192 255 Counterclockwise rolling from slow...

Страница 21: ...20 Ordercode 51315 Galactic Beam G40 Patterns...

Страница 22: ...d machine technical installations are to be inspected by a skilled person once a year The following points have to be considered during the inspection 01 All screws used for installing the device or p...

Страница 23: ...the fixture or the previous one 05 Determine whether the controller or light effect is at fault Does the controller operate properly with other DMX products If not take the controller in for repair I...

Страница 24: ...cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of...

Страница 25: ...ple units together you can make a great and cost effective beam show Beam Diameter 18mm at aperture Laser Class 3B Laser Modulation TTL Laser Safety EN IEC 60825 1 Ed 2 2007 03 Laser Color Green Laser...

Страница 26: ...25 Ordercode 51315 Galactic Beam G40 Dimensions...

Страница 27: ...26 Ordercode 51315 Galactic Beam G40...

Страница 28: ...2015 Showtec...

Отзывы: