13
Ordercode: 60906
FX Shot MKII
Testing
When testing, make sure that no electric cannons are connected via the ignition plug to the FX Shot.
01)
Test the operation of the FX Shot by connecting the Neutrik power cable to the mains power supply.
Once the blue LED above the FX Shot lights up, you know that the FX Shot is properly connected.
02)
For DMX operation also check if the blue LED lights up when activating your specific DMX setup or DJ
switch setup work.
Make sure that after testing, you disengage the switchpack.
The blue LED must be off.
03)
Carefully plug the electric cannon ignition connector into the input on top of the FX Shot. This
connector has a recess, so that the plug can only be plugged into the socket one way.
ONLY connect the ignition plug when the blue LED is OFF !!!
Be careful: Always look before plugging the connector into the socket.
If the blue LED is on, immediately stop. Disconnect the FX Shot from the mains
power supply and check your setup. If the blue LED is lit, then the cannon can
shoot off its confetti, upon receiving electric power.