17
Ordercode: 42727
Eventspot 60 Q7
6.2. Color
With this menu, you can adjust the color calibration functions.
01)
While in SETTING menu, press the
UP/DOWN
buttons to choose
COLOR
.
02)
Press the
ENTER
button to open the menu.
03)
Press the
UP/DOWN
buttons to toggle between the 3 options: RGBW, OFF or UC.
04)
If you have chosen RGBW, then RGB to WHITE is active. This means RGB = 255, 255, 255. The displayed
color is the one which you set in CALIBRATION > RGBW menu (8. Calibration, page 18).
05)
If you have chosen OFF, the RGB values are not adjusted and the output is the most powerful.
06)
If you have chosen UC, the RGB output is adjusted to a universal color which you can set in
CALIBRATION > UC menu (8. Calibration, page 18). In this way, different Eventspot versions are color-
balanced in order to match each other.
6.3. Dimmer
With this menu, you can adjust the dimmer speed.
01)
While in SETTING menu, press the
UP/DOWN
buttons to choose
DIMMER
.
02)
Press the
ENTER
button to open the menu.
03)
Press the
UP/DOWN
buttons to choose one of the 4 dimmer speed options (DIM1-DIM4, from fast to
slow) and OFF.
04)
If you choose OFF, then RGBW and the master dimmer will be linear.
6.4. DMX Error
With this menu, you can determine the device’s behaviour in case of a DMX signal error.
01)
While in SETTING menu, press the
UP/DOWN
buttons to choose
DMX ERROR
.
02)
Press the
ENTER
button to open the menu.
03)
Press the
UP
/
DOWN
buttons to toggle between the 2 options: BLACK and SAVE.
04)
If you have chosen BLACK, the Eventspot will blackout, in case of a DMX signal error.
05)
If you have chosen SAVE, the Eventspot will fall back on the last working DMX signal, which will
ensure undisrupted performance.
7. Safety lock
With this menu you can select whether the safety lock is active or not.
01)
While in the main menu, press the
UP/DOWN
buttons to choose
KEY
.
02)
Press the
ENTER
button to open the menu. The display will show:
03)
Press the
UP/DOWN
buttons to toggle between ON and OFF.
04)
If you have chosen ON and when the display turns off after remaining idle for 30 seconds, you will
need to insert the password in order to access the main menu (press the buttons in the following
order:
UP, DOWN, UP, DOWN
and press the
ENTER
button to confirm).
05)
If you have chosen OFF, the main menu will remain unlocked.
Содержание EVENTSPOT 60 Q7
Страница 14: ...13 Ordercode 42727 Eventspot 60 Q7 Menu overview...
Страница 32: ...31 Ordercode 42727 Eventspot 60 Q7 Dimensions...
Страница 33: ...32 Ordercode 42727 Eventspot 60 Q7 Notes...
Страница 34: ...33 Ordercode 42727 Eventspot 60 Q7...
Страница 35: ...34 Ordercode 42727 Eventspot 60 Q7...
Страница 36: ...2016 Showtec...