background image

 

  

 

 

   

 

Ordercode: 44100 

EventBAR 100IR 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s lifespan. 

 

Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at 
least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced to prevent its functions from being impaired, 
due to cracks or deep scratches. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of reach of children. Never leave the unit running 
unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement, use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the EventBAR 100IR. The manufacturer 
will not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electrical connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

 

Содержание EventBAR 100IR

Страница 1: ...EventBAR 100IR V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 44100 MANUAL ENGLISH...

Страница 2: ...le EventBARs 100IR Master Slave control 11 Multiple EventBARs 100IR DMX512 Mode 12 Fixture Linking 13 Data Cabling 13 Control Panel 14 DMX Control Mode 14 DMX Addressing 14 Menu overview 15 Main Menu...

Страница 3: ...2 Ordercode 44100 EventBAR 100IR Product Specifications 27 Dimensions 28 Notes 29...

Страница 4: ...operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving the...

Страница 5: ...he plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on th...

Страница 6: ...s electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do n...

Страница 7: ...h the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW CO...

Страница 8: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Страница 9: ...7 million additive colors Power Supply 100 240V AC 50 60Hz Control Mode DMX512 Dimmer 0 100 Strobe 0 20Hz Consumption Power 42 Watt 3 pin female XLR socket and 3 pin male XLR socket IEC Power In Link...

Страница 10: ...unting 02 240 RGB high intensity 10mm LEDs Backside Fig 02 03 IEC Power In fuse T1AL 250V 04 Ground Earth connection 05 Ground Earth connection 06 Power Switch On Off 07 Menu Buttons LED display 08 Sa...

Страница 11: ...full RGB 07 The Power LED indicator on the back shows the energy level of the battery 100 80 60 40 20 20 0 Important Charge the battery when the red LED energy level 20 of the LED indicator flashes Yo...

Страница 12: ...place it on the floor Leave at least 0 5 meter on all sides for air circulation 02 Plug the end of the electric mains power cord into a proper electric power supply socket 03 Use a 3 p XLR cable to co...

Страница 13: ...ink the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units 05 Supply electri...

Страница 14: ...Rs 100IR on a Power link 21 fixtures 240V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or const...

Страница 15: ...ddress of the third EventBAR should be 25 24 49 d049 etc Please be sure that you do not have any overlapping channels in order to control each EventBAR correctly If two or more EventBARs are addressed...

Страница 16: ...15 Ordercode 44100 EventBAR 100IR Menu overview...

Страница 17: ...y with its auto program Built in Programs With this menu you can choose a built in program 01 Press the Mode button on the device until the display shows 02 You can choose 20 built in programs by usin...

Страница 18: ...asily The master doesn t have any cable plugged into the DMX input connector Slave control This function allows you to control the slaves from the master s control panel in a master slave setup 01 Onl...

Страница 19: ...s menu you can create a static color 01 Press the Mode button until the display shows 02 Press the Setup button to create a specific color 03 With this submenu you can set 3 static colors of the Event...

Страница 20: ...ode Sound controlled Mode Activate Sound controlled mode Speed Mode Activate Speed mode Strobe Mode Activate Strobe mode Dimming Mode Activate Dimming Mode Plus Increase button Minus Decrease button R...

Страница 21: ...ode you can control the speed of the program by pressing the button 04 You can choose between by using the and buttons 05 You can also set the strobe of the program by pressing the button 06 With the...

Страница 22: ...m 20 240 255 Sound mode Channel 2 Preset Colors CH1 must be set between 001 011 0 27 Black 28 55 Red 56 83 Yellow 84 111 Light green 112 139 Green 140 167 Light blue 168 195 Blue 196 223 Purple 224 25...

Страница 23: ...144 155 Program 13 156 167 Program 14 168 179 Program 15 180 191 Program 16 192 203 Program 17 204 215 Program 18 216 227 Program 19 228 239 Program 20 240 255 Sound mode Channel 7 Preset Colors CH6...

Страница 24: ...be 0 20Hz color strobe selected by CH1 CH3 24 DMX Channels Channel 1 Red Section 1 0 255 Gradual adjustment Red from 0 100 Channel 2 Green Section 1 0 255 Gradual adjustment Green from 0 100 Channel 3...

Страница 25: ...ection 6 0 255 Gradual adjustment Red from 0 100 Channel 17 Green Section 6 0 255 Gradual adjustment Green from 0 100 Channel 18 Blue Section 6 0 255 Gradual adjustment Blue from 0 100 Channel 19 Red...

Страница 26: ...ow 01 Unplug the unit from electric power source 02 Insert a flat head screwdriver into a slot in the fuse cover Gently pry up the fuse cover the fuse will come out 03 Remove the used fuse If brown or...

Страница 27: ...ing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination...

Страница 28: ...Green 234 Lux 2m Blue 250 Lux 2m Full On 433 Lux 2m Beam Angle 30 Sections 8 Dimmer 0 100 Strobe 0 20Hz Color Range RGB 16 7 million additive colors Cooling convection Display LED display Housing Powe...