background image

3

  Only use device indoor, avoid contact with water or other liquids.

  Only operate the fixture after having checked that the housing is firmly closed and all screws are

tightly fastened.

  Only operate the device after having familiarized with its functions.

  Avoid flames and do not put close to flammable liquids or gases.

  Always replace the lamp, when it is damaged or deformed due to the heat.

  Always keep case closed while operating.

  Always allow free air space of at least 50 cm around the unit for ventilation.

  Always disconnect power from the mains, when device is not used, before cleaning or when

replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the
power-cord.

  Make sure that the device is not exposed to extreme heat, moisture or dust.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord

from time to time.

  If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to

cracks or deep scratches.

  If device is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

  If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Showtec dealer for service.

  For adult use only. City Painter must be installed out of the reach of children. Never leave the unit

running unattended.

  Never attempt to bypass the thermostatic switch or fuses.

  Replace the lamp if it becomes defective or worn out, or before usage exceeds the maximum service

life.

  Allow the fixture to cool down for 15 minutes, before opening the fixture and replacing lamp. Protect

your hands and eyes with gloves and safety glasses.

  For replacement use lamps and fuses of same type and rating only.

  Allow time to cool down, before replacing lamp.

  The user is responsible for correct positioning and operating of the City Painter. The manufacturer

will not accept liability for damages caused by the misuse or incorrect installation of this device.

  This device falls under protection class I. Therefore it is essential to connect the yellow/green

conductor to earth.

  During the initial start-up some smoke or smell may arise. This is a normal process and does not

necessarily mean that the device is defective.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

WARRANTY: Till one year after date of purchase.

CAUTION ! EYEDAMAGES !.

Avoid looking directly into the light source.

(meant especially for epileptics) !

Содержание City Painter 575

Страница 1: ...City Painter 575 ORDERCODE 40905 ...

Страница 2: ...y on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great light...

Страница 3: ...allation Installing the Lamp Set Up and Operation One City Painter Multiple City Painters Control Mode DMX 512 Mode Master Mode Slave Mode DMX Addressing Master Automatic Dip Switch Settings DMX Dip Switch Setting Beam Angle Structure of the Fixture Electrical Wiring Diagram Maintenance Changing the Lamp Replacing the Fuse Troubleshooting No Light No Movement All Products No Response to DMX Produc...

Страница 4: ...r caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge lamps may expose and emit a high ultraviolet radiation which may cause burns Never lift the fixture by holding it at the projector head as the mechanics may be damage...

Страница 5: ...ely The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showtec dealer for service For adult use only City Painter must be installed out of the reach of children Nev...

Страница 6: ...s Improper installation can cause serious damage to people and property Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the projector is lowered from the ceiling or high joists professional trussing systems have ...

Страница 7: ...10 holes on the base of the fixture to fasten the clamps Improper installation can cause serious damage to people and property Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place Cable Pin International BROWN FASE L BLUE NUL N YELLOW GREEN EARTH Make sure that the device is always connected pr...

Страница 8: ... required IP 54 Protection degree Stand alone control or Master Slave control Dimmer 0 100 Zoom 7 40 degrees by DMX Colors Full CMY color mixing Strobe 1 7Hz Flux 49000 Lux Color Temp 7200 Kº Lamp not included Note If the lamp has been turned OFF let the lamp cool down for 15 minutes before turning the lamp ON again Overview 1 2 Fig 1 1 Lens 2 Adjustment Screw for inclination angle ...

Страница 9: ...a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 4 screws on the aluminum housing Fig 2 Gently remove the metal housing 2 Loosen the 2 screws D and E Fig 3 on the lamp holder Remove the lamp holder 3 Read lamp instructions Do not touch the lamp bulb glass See Fig 4 ...

Страница 10: ...s 1 Leave at least 1 meter on all sides for air circulation 2 Use a 3 p 5 p XLR cable to connect the Explorers and other devices 3 Link the units as shown in figure 4 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 4 Supply electric power Plug electric mains power cords into each unit s IEC...

Страница 11: ... to use a signal amplifier The usage of a normal microphone or audio cable is suggested only for lines of max 100 meter Note Link all cables before connecting electric power Multiple City Painters Set Up DMX Set up Master Slave Set up Fig 4 Note Link all cables before connecting electric power ...

Страница 12: ...g Unit 1 1 Unit 2 9 Unit 3 17 Unit 4 25 Please be sure that you don t have any overlapping channels in order to control each City Painter correctly If two or more City Painters are addressed similarly they will work similarly For address settings please refer to the instructions under DMX 512 Mode Controlling After having addressed all City Painter fixtures you may now start operating these via yo...

Страница 13: ...5 sec CH20 10 sec CH21 30 sec CH22 sec60 Channel 23 26 Smooth Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink CH23 5 sec CH24 10 sec CH25 30 sec CH26 sec60 Channel 27 30 Rapid Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink CH27 5 sec CH28 10 sec CH29 30 sec CH30 sec60 Channel 31 34 Smooth Color Change White Red Orange Green Blue Li...

Страница 14: ... Light Blue Dark Blue Purple Rose Red Pink 10 sec 130 136 Smooth Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink 30 sec 137 143 Smooth Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink 60 sec 144 150 Rapid Color Change White Red Orange Green Blue Light Blue Rose Red 5 sec 151 157 Rapid Color Change White Red Orange Green Blue Light Bl...

Страница 15: ...13 Beam Angles ...

Страница 16: ...14 Structure of the Fixture ...

Страница 17: ...15 Electrical Wiring Diagram ...

Страница 18: ...ohol or solvents The cooling fans colour filters and the internal lenses should be cleaned monthly with a soft brush Please clean internal components once a year with a light brush and vacuum cleaner Keep connections clean Disconnect electric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric p...

Страница 19: ...e lamp Replace the old lamp with a new one with the same specifications See page 7 for replacing lamps 3 The fuse Replace the fuse See page 16 for replacing the fuse No Response to DMX Response Suspect the DMX cable or connectors a controller malfunction a light effect DMX card malfunction 1 Check the DMX cable Unplug the unit change the DMX cable then reconnect to electrical power Try your DMX co...

Страница 20: ...e is too high or too low Test the mains voltage cooling fans are not operating correctly Check the connections on the fan If the fan is faulty replace with a new one The lamp is dim The temperature in the unit is too high The air intake slits are blocked Clean the air intake slits Problem Testing Analysis Solution Check that all units are set in DMX 512 MODE The controller is not connected to the ...

Страница 21: ...ercode 80923 Electro mechanical effects DMX control via standard DMX controller IP 54 Protection degree Stand alone control or Master Slave control Dimmer 0 100 Zoom 7 40 degrees by DMX Colors Full CMY color mixing Strobe 1 7Hz Luminous Flux 49000 Lux Color Temp 7200 Kº Lamp not included Minimum distance Minimum distance from flammable surfaces 0 5m Minimum distance to lighted object 1 5m Versions...

Страница 22: ...2006 Showtec ...

Отзывы: