background image

11 

 

Multiple Galactic (DMX Control) 

1.

 

Fasten the effect light onto firm trussing Leave at least 1 meter on all sides for air circulation. 

2.

 

Always use a safety cable (ordercode 70140 / 70141). 

3.

 

Use a 3-p XLR cable to connect the Galactic lasers. 

4.

 

Link the units as shown in (figure 4), Connect a DMX signal cable from the first unit's DMX "out" socket 
to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units. 

5.

 

Supply electric power: Plug the end of the mains power cord into proper electric power supply 
sockets. Do so for all units and the controller. 

 

Multiple Galactics Set Up 

 

 
 
 
 
 
 

        

Max. 30 Galactics

 

 

Fig. 4

 

 
 
 
 

 

Note : Link all DMX cables and set dip switches before connecting electric power 

 

6.

 

Do not supply power before the whole system is set up and connected properly. Design your show 
according to your DMX controller functions. See page 16 for more about DMX programming. 

 
 

Fixture Linking

 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.   
 

Important:

  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 
 
Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of Galactics on a DMX data link: 30 fixtures 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio Certified DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3 p. > XLR/F 3 p.  

Ordercode

 FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by  
Neutrik®.

 Ordercode

 FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.). 

 

Содержание 51331

Страница 1: ...Galactic B1000 ORDERCODE 51331 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...n and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showt...

Страница 3: ...e Galactic Sound controlled Musicshow 1 2 10 Multiple Galactics Master Slave control 10 Multiple Galactic DMX Control 11 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Address...

Страница 4: ...ion and maintenance of this device have to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should the...

Страница 5: ...o extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the powe...

Страница 6: ...t Classification and Manufacturing Label Identification Laser Classification Class 4 Cooling TE Cooling Fan Cooling Laser medium wavelength 450nm blue Output 1000mW blue Scanning ILDA Standard 20K Bea...

Страница 7: ...ngers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and...

Страница 8: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 9: ...SD card slot to run pre programmed shows without any controller Power Input AC 100 240V 50 60Hz Power Consumption 40 Watt Scan Speed 20K Laser Class 4 Laser Modulation TTL Laser Safety EN IEC 60825 1...

Страница 10: ...fety Eye 16 ILDA Input 7 Lock On Off 17 ILDA Through 8 3 pin DMX Out 18 RGB ILDA LEDs 9 SD Slot 19 Microphone 10 3 pin DMX In Red ILDA LED connection Green ILDA LED disconnection All RGB LEDS on Laser...

Страница 11: ...They should be kept with the Galactic laser The following safety precautions should be followed The interlock plug should be placed on the backside 12 of your Galactic laser The keys should be put int...

Страница 12: ...music Please see page 14 for more information about the sound control options Multiple Galactics Master Slave control 1 Fasten the effect light onto firm trussing Leave at least 1 meter on all sides...

Страница 13: ...mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be dai...

Страница 14: ...address of the third Galactic should be 14 13 27 etc Please be sure that you don t have any overlapping channels in order to control each Galactic correctly If two or more Galactic s are addressed si...

Страница 15: ...13 Menu Overview...

Страница 16: ...ng show which is better suited for disco applications is a slow and relaxing show which is better suited for lounge applications 3 Use the ENTER button to store your setting Attention When there is no...

Страница 17: ...15...

Страница 18: ...MA3 ild 2 If you want to create your own preprogrammed show with these 3 files you should create a TXT file with the following contents ANIMA1 ild 12 3 ANIMA2 ild 20 1 ANIMA3 ild 18 4 3 Save this TXT...

Страница 19: ...e ENTER button to store your setting ILDA Control Mode This laser has an ILDA DB25 port meaning it can be controlled by the PC There is an auto transform set in the unit s inside to transform the ILDA...

Страница 20: ...patterns For exact values see page 20 Channel 3 Strobe 0 5 Laser OFF 6 10 Laser ON but no strobe 11 199 Strobe from slow to fast 200 255 Sound controlled Strobe Channel 4 X axis Moving 0 125 125 diff...

Страница 21: ...ng the images 75 104 Clipping Out from slow to fast drawing clockwise 105 144 Clipping In from slow to fast drawing counterclockwise 145 184 Clipping Out and In from slow to fast 185 224 Clipping On f...

Страница 22: ...222 224 018 020 069 071 120 122 174 176 225 227 021 023 072 074 123 125 177 179 228 230 024 026 075 077 126 128 180 182 231 233 027 029 078 080 129 131 183 185 234 236 030 032 081 083 132 134 186 188...

Страница 23: ...ghound ild Animation Feelup ild spcity ild Heron ild Animation PRG flying ild Sphinxx ild Animals hippo ild arro3f ild GRIDDOTS ild sphinxxx ild 3D2DRudy ild horse3 ild Balaim ild KLF ild sydneop ild...

Страница 24: ...alanim ild FIREWRK4 ild Pirate2 ild bass ild FOOTYT ild wfall ild Food ild pullgun ild bbcmic ild Ford ild wfallzom ild Games ild rhood ild behind ild Harley ild North ild runna ild bells ild Holden i...

Страница 25: ...d LOVE2 ild sship4 ild Music ild Wave sshipA ild Party ild 2wave ild sshipb ild Ready ild circle_w ild starexpl ild Start ild dot_wave ild teargas ild Stop ild d_wave ild thermo ild Text PRG free ild...

Страница 26: ...4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product specification label for details Tr...

Страница 27: ...efective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination...

Страница 28: ...40 Watt Scan Speed 20K Laser Class 4 Laser Modulation TTL Laser Safety EN IEC 60825 1 Ed 2 2007 03 Laser Power 1000mW 450nm Blue Scan Angle 40 2 x Auto Show 2 x Music Show 85 Animated Graphic Show Pat...

Страница 29: ......

Отзывы: