Wipe Out 3W 

Problem 

Probable cause(s) 

Remedy 

 

 

 

One or more 
fixtures do not 
function at all. 

No power to the fixture. 

 

Check if power is switched on and 
cables are plugged in. 

Primary fuse blown. 

 

Replace fuse. 

 

 

 

Fixtures reset 
correctly, but all 
respond erratically 
or not at all to the 
controller. 

The controller is not connected. 

 

Connect controller. 

3-pin XLR Out of the controller does 
not match XLR Out of the first fixture 
on the link (i.e. signal is reversed). 

 

Install a phase reversing cable between 
the controller and the first fixture on the 
link. 

 

 

 

Fixtures reset 
correctly, but some 
respond erratically 
or not at all to the 
controller. 

Poor data quality 

 

Check data quality. If much lower than 
100 percent, the problem may be a 
bad data link connection, poor quality 
or broken cables, missing termination 
plug, or a defective fixture disturbing 
the link. 

Bad data link connection 

 

Inspect connections and cables. 
Correct poor connections. Repair or 
replace damaged cables. 

Data link not terminated with 120 
Ohm termination plug. 

 

Insert termination plug in output jack of 
the last fixture on the link. 

Incorrect addressing of the fixtures. 

 

Check address setting. 

One of the fixtures is defective and 
disturbs data transmission on the 
link. 

 

Bypass one fixture at a time until normal 
operation is regained: unplug both 
connectors and connect them directly 
together. 

 

Have the defective fixture serviced by a 
qualified technician. 

3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

 

Install a phase-reversing cable between 
the fixtures or swap pins 2 and 3 in the 
fixture. 

 

 

 

No light or lamp 
cuts out 
intermittently 

Fixture is too hot. 

 

Allow fixture to cool. 

 

Make sure air vents at control panel 
and front lens are not blocked. 

 

Turn up the air conditioning . 

LEDs damaged 

 

Disconnect fixture and return to your 
dealer. 

The power supply settings do not 
match local AC voltage and 
frequency. 

 

Disconnect fixture. Check settings and 
correct if necessary. 

 
 

 

Содержание 42567

Страница 1: ...Wipe Out 3W V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42567 MANUAL ENGLISH...

Страница 2: ...Outs Master Slave control 8 Multiple Wipe Outs DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview 12 Main Menu Options 13 1 Auto Run Mod...

Страница 3: ...factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all LEDs are us...

Страница 4: ...handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is n...

Страница 5: ...thers Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried...

Страница 6: ...a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief descr...

Страница 7: ...power cable DMX control via standard DMX controller On Board LCD display for easy setup Control modes Auto Built in programs Sound controlled DMX 512 Master Slave Divided in 2 sections and equipped w...

Страница 8: ...pin DMX signal connector IN 03 IEC power connector 100 240V IN Fuse T2AL 250V 04 Ground earth connection 05 Power switch ON OFF 06 LCD display menu buttons 07 IEC power connector 100 240V OUT 08 3 pin...

Страница 9: ...de 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Wipe Out is not connected with a DMX cable it functions as a stand alone device 0...

Страница 10: ...ices 05 Link the units as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 0...

Страница 11: ...s on a power link 16 fixtures 240V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct yo...

Страница 12: ...uld be 17 16 33 033 etc Please be sure that you do not have any overlapping channels in order to control each Wipe Out correctly If two or more Wipe Outs are addressed similarly they will work similar...

Страница 13: ...12 Ordercode 42567 Wipe Out 3W Menu Overview...

Страница 14: ...y shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to choose one of the 2 options LED Menu BAR Menu 04 Press the SETUP button to enter the desired menu 1 1 LED Menu 01 Pre...

Страница 15: ...ress the SETUP button to enter the flash frequency settings 15 Press the UP DOWN buttons to increase decrease the flash frequency The adjustment range is between from low to high frequency 1 2 Bar Men...

Страница 16: ...u you can set the DMX address 01 Press the MODE button until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to choose one of the following 2 options DMX addr...

Страница 17: ...s voltage Product specification 04 When the display shows press the SETUP button to open the menu 05 Press the UP DOWN buttons to set the time after which the display turns off There are 5 options to...

Страница 18: ...Press the SETUP button to see the device s voltage 14 When the display shows press the SETUP button to enter the product specification menu 15 Press the UP DOWN buttons to toggle between the following...

Страница 19: ...adual adjustment from dark to brightest 0 100 Channel 6 Dimmer intensity LED2 0 255 Gradual adjustment from dark to brightest 0 100 Channel 7 Dimmer intensity LED3 0 255 Gradual adjustment from dark t...

Страница 20: ...D3 CH13 must be open 0 255 Gradual adjustment from dark to brightest 0 100 Channel 8 Dimmer intensity LED4 CH13 must be open 0 255 Gradual adjustment from dark to brightest 0 100 Channel 9 Dimmer inte...

Страница 21: ...d machine technical installations are to be inspected by an expert after every year in the course of an acceptance test The operator has to make sure that safety related and machine technical installa...

Страница 22: ...cing the fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Wipe Out as this may damage the unit and the wa...

Страница 23: ...connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the...

Страница 24: ...ibilities DMX control via standard DMX controller On Board Display for easy setup Control Auto Built in programs Sound controlled DMX 512 Master Slave Quick lock mounting brackets included which makes...

Страница 25: ...24 Ordercode 42567 Wipe Out 3W Dimensions...

Страница 26: ...25 Ordercode 42567 Wipe Out 3W Notes...

Страница 27: ...26 Ordercode 42567 Wipe Out 3W...

Страница 28: ...2015 Showtec...

Отзывы: