background image

 

  

 

 

   

 

Ordercode: 42199 

LED Light Bar 8 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s lifespan. 

 

Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at 
least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced to prevent its functions from being impaired, 
due to cracks or deep scratches. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of reach of children. Never leave the unit running 
unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement, use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Light Bar 8. 

 

The manufacturer will not accept liability for damages caused by the misuse or incorrect installation 
of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electrical connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

 

Содержание 42199

Страница 1: ...LED light bar 8 V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42199 MANUAL ENGLISH...

Страница 2: ...ars Master Slave control 8 Multiple Light Bars DMX512 Mode 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11 Menu overview 12 Main Menu Options 14 1 DMX Mode...

Страница 3: ...gher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving...

Страница 4: ...the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on...

Страница 5: ...ized dealer Procedure If the projector is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the projector with the mounting bracket to the trus...

Страница 6: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 7: ...s Power 60 Watt 3 pin female XLR socket and 3 pin male XLR socket IEC Power In and IEC power Out Max 10A Linkable via 3 pin XLR cable Built in microphone Black aluminum material LED Digital display Fu...

Страница 8: ...ct to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product...

Страница 9: ...ou have pressed enter then the fixture will react to the beat of the music Please see page 15 for more information about the Sound controlled mode Multiple Light Bars Master Slave control 01 Fasten th...

Страница 10: ...s as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units 05 Supply electric power Plug...

Страница 11: ...ou must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade c...

Страница 12: ...ss of the first Light Bar should be 1 A001 the DMX address of the second Light Bar should be 1 26 27 A027 the DMX address of the third Light Bar should be 27 26 53 A053 etc Please be sure that you do...

Страница 13: ...12 Ordercode 42199 LED Light Bar 8 Menu overview...

Страница 14: ...13 Ordercode 42199 LED Light Bar 8...

Страница 15: ...nels 14 Channels 26 Channels 2 Channels 7 Channels 2 Master slave addressing Master 01 The default setting for this device is master 02 Only one fixture can be the master Note Disconnect the fixture f...

Страница 16: ...an set the sensitivity from low sensitivity to high sensitivity between SU 00 SU 31 with the Up and Down buttons 4 Static Color Mode With this menu you can set the static color 01 Press the MODE butto...

Страница 17: ...en Blue Flash from 00 99 Blue Flash from 00 99 Red Blue Flash from 00 99 Red Green Blue Flash from 00 99 Off Speed from 01 99 Full Flash Frequency 00 99 Fade Time from 00 99 Speed from 01 99 Full Flas...

Страница 18: ...17 Ordercode 42199 LED Light Bar 8 Examples Menu 21 Menu 22...

Страница 19: ...display shows 02 With this menu you can set the Auto Mode of the LED Light Bar 03 Press Setup to enter the AUTO Menu You can choose 4 different sub menus Number of Loops from 01 100 Speed from 01 99...

Страница 20: ...justment Green from 0 100 Channel 3 Blue Dimmer must be open 0 255 Gradual adjustment Blue from 0 100 Channel 4 Master Dimmer 0 255 Dimmer from closed to open 0 100 14 DMX Channels d P3 Channel 1 Red...

Страница 21: ...l adjustment Blue from 0 100 Channel 13 Strobe Dimmer must be open 0 10 Shutter Open 11 255 Strobe effect from slow to fast Channel 14 Master Dimmer 0 255 Dimmer from closed to open 0 100 26 DMX Chann...

Страница 22: ...tion 5 0 255 Gradual adjustment Green from 0 100 Channel 15 Blue Section 5 0 255 Gradual adjustment Blue from 0 100 Channel 16 Red Section 6 0 255 Gradual adjustment Red from 0 100 Channel 17 Green Se...

Страница 23: ...103 Program 5 104 111 Program 6 112 119 Program 7 120 127 Program 8 128 135 Program 9 136 143 Program 10 144 151 Program 11 152 159 Program 12 160 167 Program 13 168 175 Program 14 176 183 Program 15...

Страница 24: ...gram 6 112 119 Program 7 120 127 Program 8 128 135 Program 9 136 143 Program 10 144 151 Program 11 152 159 Program 12 160 167 Program 13 168 175 Program 14 176 183 Program 15 184 191 Program 16 192 19...

Страница 25: ...wipe the cover with a damp cloth Wipe the front glass panel clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front glass panel will require weekly cleaning as smoke fluid...

Страница 26: ...g the fuse 04 If all of the above appears to be in order switch the unit on again 05 If you are unable to determine the cause of the problem do not open the LED Light Bar 8 as this may damage the unit...

Страница 27: ...data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output j...

Страница 28: ...otal 240 LEDs Output 800Lumen Lux 2m 613 3 Efficacy lm W 36W Beam Angle 30 Refresh rate 400Hz Max Distance 15m Sections 8 Dimmer 0 100 Strobe 0 20Hz Color Range RGB Housing Black aluminum material DMX...

Страница 29: ...28 Ordercode 42199 LED Light Bar 8 Dimensions...

Страница 30: ...29 Ordercode 42199 LED Light Bar 8 Notes...

Страница 31: ...30 Ordercode 42199 LED Light Bar 8...

Страница 32: ...2016 Showtec...

Отзывы: