background image

 

  

 

 

   

 

Ordercode: 42199 

LED Light Bar 8 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause of the 
return. Be sure to properly pack fixture as any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name. 

02)

 

Your address. 

03)

 

Your phone number. 

04)

 

A brief description of the symptoms. 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that the fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
agreed otherwise in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period, complaints will not be handled anymore. 
Complaints will only be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

Содержание 42199

Страница 1: ...LED light bar 8 V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42199 MANUAL ENGLISH...

Страница 2: ...ars Master Slave control 8 Multiple Light Bars DMX512 Mode 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11 Menu overview 12 Main Menu Options 14 1 DMX Mode...

Страница 3: ...gher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving...

Страница 4: ...the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on...

Страница 5: ...ized dealer Procedure If the projector is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the projector with the mounting bracket to the trus...

Страница 6: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 7: ...s Power 60 Watt 3 pin female XLR socket and 3 pin male XLR socket IEC Power In and IEC power Out Max 10A Linkable via 3 pin XLR cable Built in microphone Black aluminum material LED Digital display Fu...

Страница 8: ...ct to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product...

Страница 9: ...ou have pressed enter then the fixture will react to the beat of the music Please see page 15 for more information about the Sound controlled mode Multiple Light Bars Master Slave control 01 Fasten th...

Страница 10: ...s as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units 05 Supply electric power Plug...

Страница 11: ...ou must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade c...

Страница 12: ...ss of the first Light Bar should be 1 A001 the DMX address of the second Light Bar should be 1 26 27 A027 the DMX address of the third Light Bar should be 27 26 53 A053 etc Please be sure that you do...

Страница 13: ...12 Ordercode 42199 LED Light Bar 8 Menu overview...

Страница 14: ...13 Ordercode 42199 LED Light Bar 8...

Страница 15: ...nels 14 Channels 26 Channels 2 Channels 7 Channels 2 Master slave addressing Master 01 The default setting for this device is master 02 Only one fixture can be the master Note Disconnect the fixture f...

Страница 16: ...an set the sensitivity from low sensitivity to high sensitivity between SU 00 SU 31 with the Up and Down buttons 4 Static Color Mode With this menu you can set the static color 01 Press the MODE butto...

Страница 17: ...en Blue Flash from 00 99 Blue Flash from 00 99 Red Blue Flash from 00 99 Red Green Blue Flash from 00 99 Off Speed from 01 99 Full Flash Frequency 00 99 Fade Time from 00 99 Speed from 01 99 Full Flas...

Страница 18: ...17 Ordercode 42199 LED Light Bar 8 Examples Menu 21 Menu 22...

Страница 19: ...display shows 02 With this menu you can set the Auto Mode of the LED Light Bar 03 Press Setup to enter the AUTO Menu You can choose 4 different sub menus Number of Loops from 01 100 Speed from 01 99...

Страница 20: ...justment Green from 0 100 Channel 3 Blue Dimmer must be open 0 255 Gradual adjustment Blue from 0 100 Channel 4 Master Dimmer 0 255 Dimmer from closed to open 0 100 14 DMX Channels d P3 Channel 1 Red...

Страница 21: ...l adjustment Blue from 0 100 Channel 13 Strobe Dimmer must be open 0 10 Shutter Open 11 255 Strobe effect from slow to fast Channel 14 Master Dimmer 0 255 Dimmer from closed to open 0 100 26 DMX Chann...

Страница 22: ...tion 5 0 255 Gradual adjustment Green from 0 100 Channel 15 Blue Section 5 0 255 Gradual adjustment Blue from 0 100 Channel 16 Red Section 6 0 255 Gradual adjustment Red from 0 100 Channel 17 Green Se...

Страница 23: ...103 Program 5 104 111 Program 6 112 119 Program 7 120 127 Program 8 128 135 Program 9 136 143 Program 10 144 151 Program 11 152 159 Program 12 160 167 Program 13 168 175 Program 14 176 183 Program 15...

Страница 24: ...gram 6 112 119 Program 7 120 127 Program 8 128 135 Program 9 136 143 Program 10 144 151 Program 11 152 159 Program 12 160 167 Program 13 168 175 Program 14 176 183 Program 15 184 191 Program 16 192 19...

Страница 25: ...wipe the cover with a damp cloth Wipe the front glass panel clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front glass panel will require weekly cleaning as smoke fluid...

Страница 26: ...g the fuse 04 If all of the above appears to be in order switch the unit on again 05 If you are unable to determine the cause of the problem do not open the LED Light Bar 8 as this may damage the unit...

Страница 27: ...data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output j...

Страница 28: ...otal 240 LEDs Output 800Lumen Lux 2m 613 3 Efficacy lm W 36W Beam Angle 30 Refresh rate 400Hz Max Distance 15m Sections 8 Dimmer 0 100 Strobe 0 20Hz Color Range RGB Housing Black aluminum material DMX...

Страница 29: ...28 Ordercode 42199 LED Light Bar 8 Dimensions...

Страница 30: ...29 Ordercode 42199 LED Light Bar 8 Notes...

Страница 31: ...30 Ordercode 42199 LED Light Bar 8...

Страница 32: ...2016 Showtec...

Отзывы: