SL PAR 155 ZOOM RGBW LED Luminaire Main Menu Options
19
SL PAR 155 ZOOM RGBW LED Luminaire
Installation & User’s Manual
Sh wline
Settings/DMX
DMX configuration options are available in the DMX menu.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the fixture's DMX
settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in
Table 9.
Settings/Display
Options of the fixture's LCD display can be adjusted in the Display menu.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the fixture's DMX
settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in
Table 10.
Lock Fixture
You can lock all fixture functions, requiring a PIN code to access the menu functions. When you select this menu
item, you are asked to confirm that you wish to lock the fixture. Once locked, all menu items can only be accessed by
entering one of the three PIN codes assigned in the Settings/Security menu. (see
"Settings/Security" on page 17
for
more information). The PIN code used to unlock the fixture will only unlock the functionality assigned to that
particular PIN code.
Note:
When the fixture is powered off, the Lock Fixture function will be disabled. To assign fixture power-up
security refer to (see
"Settings/Security" on page 17
for more information).
Table 8: Factory Default Parameters
Parameter
Description
Protected
•
No - all menu items are able to be restored to factory defaults.
•
Preset & Chase - user edited Presets and Chases are not able to be restored to fac-
tory defaults.
Load Factory
•
No - no action.
•
Yes - restore to factory default menu settings.
Table 9: DMX Setting Parameters
Parameter
Description
DMX Enable
•
Enable - Fixture will respond to DMX commands/signals.
•
Disable - Fixture will ignore DMX commands/signals.
Address
Assigns the fixture’s DMX start address.
Map
Selects the DMX map for the fixture to use (see
DMX CONTROL
section for more
information).
When no DMX
Selects the action of the fixture when the unit is powered ON and not receiving DMX.
•
Off - Turn off all LED output.
•
Last Action - restore the last menu action.
•
Power-up - follow the power-up value in the settings menu.
•
Hold - continue with the last DMX values received.
Table 10: LCD Display Parameters
Parameter
Description
Flip Display
•
Yes - The display will be inverted.
•
No - The display will not be inverted.
•
Auto - The display will automatically invert depending upon fixture orientation.
Off Time
Assign a time for the display to automatically turn off after the last button press. A value of
ON will leave the display on indifferently.
Language Select
English is the only language currently supported.