OPERATION AND PROGRAMMING
Sh wline
Use the Up and Down buttons to select security PIN codes. Press the Check button and then use Left and Right and
Up Down buttons to assign the pin code. Press the Check button to save the new PIN code.
The Power-Up Level parameter assigns a lock level to the fixture when power is applied. Use the Up and Down
buttons to select the Power-Up Level, and then use the Left and Right buttons to select the Power-up Level option.
Settings/General
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different general
fixture settings. When finished, press the Check button to exit the menu level. The adjustable parameters are
described in Table 7.
Settings/Factory Default
Factory default menu settings can be recalled through this menu option. You can select if you wish to overwrite the
user edited preset and chases.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different settings.
When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 8.
Table 5: Security Lock Levels
Lock Level
Menu Functions Affected
Level 1
Edit Presets, Edit Chases, and Settings Menu
Level 2
Settings Menu
Level 3
All
Table 6: PIN Level Parameters
Parameter
Description
Enter Pass PIN
Enter a PIN code matching the level codes assigned in the Settings/Security menu to
toggle the current security level.
Level 1 PIN
Edit the PIN code used to toggle the Level 1 security.
Level 2 PIN
Edit the PIN code used to toggle the Level 2 security.
Level 3 PIN
Edit the PIN code used to toggle the Level 3 security.
Power-up Level
Select the security level to default to when the fixture is powered ON.
•
Disable PIN will disable all security functions.
•
Locked will lock all functions.
Table 7: General Level Parameters
Parameter
Description
Power-Up
Select the action of the fixture when the unit is powered ON. You can select from Off, Last
Set, Color filters, presets, and chases.
Mode
Select either Master/Slave (see
Master / Slave Operational Mode
for more information).
Dim Response
Select Normal, Incandescent, or Reduced dimming response.
•
Normal: Fixture LEDs dim with a normal response.
•
Incandescent: Fixture LED’s dim with an incandescent emulation response. The
response to dimming commands will be slightly delayed at lower intensities.
•
Reduced: The response to dimming commands will be calculated with a smaller algo-
rithm to provide emulation with other manufacturer's products.
Dimming Curve
Select one of four dimming curve choices (see
Dimming Curve Selection
for more
information).
Calibration
Toggle Harmonize Color Calibration on or off (see
Harmonize Color Calibration
for more
information).
Fan Control
Select Auto of Off fan operation (see
DMX Control Channel Settings
for more
information).