4
EXP. OPERATION FUNCTIONS
126
EXP. OPERATION FUNCTIONS
Chapter
4
■
Average time on digital zero
0.000 to 5.000 sec
Initial value: 0.000 sec
How to set
Inputting 0.001 sec. or more makes the above operation effective.
4-3.
RUN Output Selection
You can select the output form of the external output signal RUN (A9).
- ON-OFF operation
See "5-22.RUN Output" in the operation manual (Standard) of the DS-6200
- ON fixed
- OFF fixed
The ON-OFF relationship is the inverse of the ON-fixed case.
■
RUN output selection
ON-OFF operation / ON fixed / OFF fixed
Initial value
ON-OFF operation
How to set
ホ ー ル ド 検 出 時 間
区 間 ( I)
D Z
Example) Time specified section average hold
Averaging by the Average Time On Digital Zero
Upon completion of averaging, the ave
Hold Section
Time
Section (1)
rage result is subtracted from the value
indicated at that time.
starts at the time when Digital Zero is executed.
SET.
Exp. Operat. Set.
Page 1
→
→
Exp. Setting
→
CAUTION
In the case of using ZT (Zero Tracking) with this function effective,
averaging is also performed.
RUN
OFF
ON
3.0sec
Turns OFF when an error occurs.
RUN
OFF
ON
Error factor removal
Turns ON in 3.0 sec. by the error factor removal.
SET.
Exp. Operat. Set.
Page 1
→
→
Exp. Setting
→
CAUTION
Be aware that judgment is difficult if a hardware error occurs (if the level is fixed
for some reason) when the output is fixed.