background image

 

  

 

 

19 

   

 

Ordercode: 30749 

Edison Bar E6 

Product Specifications 

 
Model: 

Showtec Edison Bar E6 

Input voltage: 

230 V AC, 50 Hz 

Power consumption: 

130 W 

Fuse: 

T2AL/250V 

Dimensions: 

1041 x 135 x 170 mm (LxWxH) 

Weight: 

5 kg 

 
Electro-mechanical effects: 
Light source: 

6 x LED bulb (not included); 
Use only dimmable LED bulbs. 

Lamp socket: 

E27 

Control modes:  

Auto, Manual, Sound-controlled, Master/Slave, DMX-512 

DMX channels: 

1, 6 channels 

Onboard:  

LCD display for easy setup 

Housing: 

Metal & flame retardant plastic 

Color: 

Black 

Connections: 

Pro power connector IN(Blue)/OUT(Gray), 3-pin DMX 
IN/OUT 

 
Lamp:* 

83260

 – LED Filament Bulb E27 (4 W) 

83261

 – LED Filament Bulb E27 (5 W) 

83262

 – LED Filament Bulb E27 (5 W) 

83264

 – LED Filament Bulb E27 (5 W) 

83266

 – LED Filament Bulb T9, Crossed Filament (300 mm) 

83267

 – LED Filament Bulb T9, Crossed Filament (225 mm) 

83268

 – LED Filament Bulb T9, Crossed Filament (185 mm) 

83269

 – LED Filament Bulb T9, Straight Filament (300 mm) 

83270

 – LED Filament Bulb T9, Straight Filament (225 mm)

 

83271

 – LED Filament Bulb T9, Straight Filament (185 mm) 

83275

 – LED Filament Bulb BT180 (6 W) 

83276

 – LED Filament Bulb BT118 (6 W) 

83277

 – LED Filament Bulb G200 (6 W) 

83278

 – LED Filament Bulb PS52 (6 W) 

83279

 – LED Filament Bulb PS35 (6 W) 

83280

 – LED Filament Bulb BTT80 (6 W) 

83281

 – LED Filament Bulb R160 (6 W)

 

 
Max. ambient temperature t

a

:  

40 °C 

Max. housing temperature t

B

70 °C 

 

 

Minimum distance: 

 

Minimum distance from flammable surfaces: 

0,5 m 

Minimum distance to lighted object: 

1 m 

 
*: Versions for other lamps may be produced. Please check the specification label on your product. 
 
 
 
 
 
 
 
 
 
 
 
 
Design and product specifications are subject to change without prior notice. 
 

 

Website: 

www.Showtec.info

  

Email: 

[email protected] 

 

 

Содержание Edison Bar E6

Страница 1: ...Edison Bar E6 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30749 MANUAL ENGLISH ...

Страница 2: ...ons Master Slave control 10 Multiple Edisons DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 14 1 Run Mode 14 1 1 DMX Mode 15 1 2 Sound controlled Mode 15 1 3 Auto Mode 15 1 4 Manual 15 2 Pixel Inversion 15 3 DMX Fail 16 4 Reset 16 5 DMX Addressing 16 DMX Channels 16 1 Channel 16 6 Channels 16 Maintenance 17 Ch...

Страница 3: ...hipment includes Showtec Edison Bar E6 Pro power cable 1 3 m 2 x mounting bracket User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before the initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do n...

Страница 4: ...ce is not used or before cleaning or when replacing lamp Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power...

Страница 5: ...he warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedur...

Страница 6: ...n with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make sure that the device is always properly connected to the earth Improper installation can cause serious injur...

Страница 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of mer...

Страница 8: ...ories 75150 Quicklock Bracket 83260 LED Filament Bulb E27 4 W 83261 LED Filament Bulb E27 5 W 83262 LED Filament Bulb E27 5 W 83264 LED Filament Bulb E27 5 W 83266 LED Filament Bulb T9 Crossed Filament 300 mm 83267 LED Filament Bulb T9 Crossed Filament 225 mm 83268 LED Filament Bulb T9 Crossed Filament 185 mm 83269 LED Filament Bulb T9 Straight Filament 300 mm 83270 LED Filament Bulb T9 Straight F...

Страница 9: ...DMX signal connector IN 13 Fuse T2AL 250V 14 230 V pro power connector IN Blue 15 Power switch ON OFF 16 Safety eye Installation Remove all packing materials from the Edison Bar E6 Check if all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or serv...

Страница 10: ... 185 mm 83275 LED Filament Bulb BT180 6 W 83276 LED Filament Bulb BT118 6 W 83277 LED Filament Bulb G200 6 W 83278 LED Filament Bulb PS52 6 W 83279 LED Filament Bulb PS35 6 W 83280 LED Filament Bulb BTT80 6 W 83281 LED Filament Bulb R160 6 W Use only the appropriate lamp for your unit Note that product versions that use other lamps may be offered in the future Check your product specification labe...

Страница 11: ... into a proper electric power supply socket 04 Turn on the music If the device is set to sound control then the Edison will react to the beat of the music Please see page 15 for more information about the sound control options Multiple Edisons Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable or...

Страница 12: ... light controller to the first unit s DMX in socket using a DMX cable Connect the first unit s out socket with the second unit s in socket using a DMX cable Repeat this process to link the rest of the units 05 Supply electric power Plug electric mains power cords into each unit s pro power IN socket then plug the other end of the mains power cord into proper electric power supply sockets starting ...

Страница 13: ...ealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Order code FL01150 1 5 m FL013 3 m FL016 6 m FL0110 10 m FL0115 15 m FL0120 20 m DAP Audio X t...

Страница 14: ... of the third Edison should be 7 6 13 013 etc Please be sure that you do not have any overlapping channels in order to control each Edison correctly If two or more Edisons are addressed similarly they will work similarly Controlling After having addressed all Edison fixtures you may now start operating these via your lighting controller Note After switching on the Edison will automatically detect ...

Страница 15: ...ode Pixel Inversion DMX Fail Reset DMX Addressing 1 Run Mode In this menu you can set the desired operation mode 01 In main menu press the MENU button until the display shows 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to choose one of the 4 operation modes DMX mode Sound controlled mode Auto mode Manual mode 04 Press the ENTER button to open the desired menu ...

Страница 16: ...confirm 03 Press the UP DOWN buttons to choose one of the 2 menus Program choice Program speed 04 Press the ENTER button to open the desired menu If you have opened press the UP DOWN buttons to choose one of the 16 built in programs If you have opened press the UP DOWN buttons to set the program speed The adjustment range is 1 99 from slow to fast 05 Press the ENTER button to confirm save changes ...

Страница 17: ... 05 If you have chosen YES the default factory settings will be restored 5 DMX Addressing In this menu you can set the DMX address 01 In main menu press the MENU button until the display shows 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to select the required address The adjustment range is 001 512 04 Press the ENTER button to save changes DMX Channels 1 Channel Channel...

Страница 18: ...g and replacing lamp 03 Follow directions for installing the lamp page 9 Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a flat headed screwdriver into a slot in the fus...

Страница 19: ... respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not termina...

Страница 20: ... T9 Crossed Filament 300 mm 83267 LED Filament Bulb T9 Crossed Filament 225 mm 83268 LED Filament Bulb T9 Crossed Filament 185 mm 83269 LED Filament Bulb T9 Straight Filament 300 mm 83270 LED Filament Bulb T9 Straight Filament 225 mm 83271 LED Filament Bulb T9 Straight Filament 185 mm 83275 LED Filament Bulb BT180 6 W 83276 LED Filament Bulb BT118 6 W 83277 LED Filament Bulb G200 6 W 83278 LED Fil...

Страница 21: ...20 Ordercode 30749 Edison Bar E6 Dimensions ...

Страница 22: ...21 Ordercode 30749 Edison Bar E6 Notes ...

Страница 23: ...22 Ordercode 30749 Edison Bar E6 ...

Страница 24: ... 2019 Showtec ...

Отзывы: