1.1  Symbols. 

  Indicates hazardous situations and warnings. Carefully read the parts of the user manual marked with 

this symbol. 

  Indicates that work must not be performed on live electrical devices. This work may only begin after all 

suitable safety measures required by current international and/or national regulations are taken. 
1.2  Notes on graphics. 
Used the following printing types: 

 

glossary of terms: italic; 

 

the words "product", "customer manual" and "installation manual" highlighted. 

1.3  Glossary. 
1.  Customer manual: document intended for the end user that 

illustrates how to use the product. 

2.  Power cord: flexible cord, for power supply, attached to the 

device. 

3.  Pump: electromechanical device used to move air. 
4.  Inlet: product input (IN). 
5.  Outlet: the product’s exit (OUT).

 

 

6.  Flowrate:  the amount of fluid  (water)  that  crosses  a  section 

in a unit of time. 

7.  Head: this is the maximum distance that a pump can lift water for. 
8.  Flooded: if the pump is positioned at a level below the water level to be sucked. 
9.  Bearing: this is a mechanical device used to reduce attrition between two rotating objects. 
10. Rotor: it indicates all the rotating components of the pump
11. Impeller:  The  front  part  of  the  rotor,  made  up  of  a  plastic  disc  with  small  blades.  With  its  rotation,  it 

transmits to the water the necessary mechanical energy to move water from the inlet to the outlet area. 

12. Mechanical seal: a mechanical device is liable to isolating the two environments, among which there is 

a shaft with a circular motion. 

13. Dry operation: means the product’s operation without water. 
14. Thermal protector: the device that cuts of power to the product if the product overheats. 
15. Protection  device:  device  whose  operations  prevent  hazardous  situations  in  abnormal  operating 

conditions. 

16. Contact  switch  disconnection:  disconnection  of  both  power  conductors  with  a  single  contact  opening 

action. 

17. Residual  Current  Device:  (RCD)  also  called  fuse,  it  is  an  electro-technical  device  able  to  cut  off  the 

circuit in the event of fault. 

18. Hydraulic  parts:  components  used  to  create  the  system  where  the  product  is  used  (pipes,  valves, 

couplings, hose connections, etc.). 

19. Pool: artificial tank filled with water general intended for swimming or other aquatic activities. 
20. Filter: a device where the water flowing in order to retain and/or eliminate the solid particles suspended. 
21. Power  plug:  mechanical  connector  that  can  be  inserted  in  a  complementary  electrical  socket  (power 

outlet). 

22. Maximum working pressure: maximum pressure the product is able to sustain during operations. 
23. Tool:  screwdriver,  coin  or  any  other  object  that  can  be  used  to  move  a  screw  or  similar  fastening 

device. 

24. Necessary clearance: minimum product installation area. 

 

2.1  Warranty. 

  General aspects. 

i.  In accordance with these provisions, the dealer guarantees that the product covered by this warranty 

(“the product”) does not have any compliancy defect upon delivery. 

ii.  The product is guaranteed for two (2) years from the date of delivery to the purchaser. 

 

Fig. 1 

IN

OUT

Содержание WP7000

Страница 1: ...Nome file File name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 1 18 WP7000 WP8000 CUSTOMER MANUAL EN INSTALLATION MANUAL EN...

Страница 2: ...Nome file File name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 2 18...

Страница 3: ...onditions 8 5 3 Transport 8 5 4 Handling 8 5 5 Positioning 8 5 6 Connections and start up 10 Hose connection 11 Priming 11 5 7 Reinstallation and reuse 12 5 8 Demolition and disposal 12 Electric elect...

Страница 4: ...12 Mechanical seal a mechanical device is liable to isolating the two environments among which there is a shaft with a circular motion 13 Dry operation means the product s operation without water 14...

Страница 5: ...ts components and materials such as rotors bearings light bulbs o rings gaskets sponges cartridges etc that provided in the documentation that accompanies the product shall be observed iii The warrant...

Страница 6: ...ing on the product Attention to the moving parts Attention to the inlet outlet points because they can trap parts of the body and or hair and cause serious personal injuries and even death It is compu...

Страница 7: ...13 Power cord 14 Capacitor 15 Cover The hydraulic parts used for the building of the system which shall include the product modify the performance head and flowrate of the product WP7000 WP8000 Power...

Страница 8: ...perature 10 C 14 F to 60 C 140 F 5 3 Transport Handle the product with care to avoid damages The product is delivered suitably protected against transport damages However handle with care to avoid dam...

Страница 9: ...ming pool from which water is drawn Fig 11 Considering the following aspects is recommended Dimensions and position of hydraulic components Necessary clearance Fig 12 Power cord position Location of t...

Страница 10: ...Connections and start up The electrical system must meet current international and or national regulations The product must be connected to an power outlet equipped with a residual current device with...

Страница 11: ...inlet pipe hydraulic part to the IN rubber holder Fig 0 D and the outlet pipe to the OUT rubber holder Fig 0 E Fix the pipes hydraulic part with clips Fig 0 F Fig 20 Check the hydraulic pipe is as sh...

Страница 12: ...he end of its working life Therefore the user must take equipment to electronic and electro technical waste collection centres at the end of its working life or return it to the dealer when purchasing...

Страница 13: ...the control command devices Power plug with residual current device RCD when included Before turning on the product always press the RESET button Check power plug with residual current device operati...

Страница 14: ...Product components that due to their normal use suffer wear and or tear must be regularly replaced to ensure good product performance The following table shows the perishables and or consumables used...

Страница 15: ...s incorrectly installed Check correct gasket and o ring installation Contact specialised technicians 14 Water leak Fast connections or cover not tight Tighten fast connections and cover Contact specia...

Страница 16: ...or worn components as quickly as possible use only original spare parts Fig 30 WP7000 WP8000 1 XQ708I23 2a XQ710I23 2b XQ700I23 2c XQ709I23 3 XQ711I10 32 38 mm 4 XQ711I20 38 mm 5 XQ712I13 6 XQ713I23...

Страница 17: ...Nome file File name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 17 18...

Страница 18: ...name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 18 18 SHOTT INTERNATIONAL S R L VIA DELLE PEZZE 35 35013 CITTADELLA PD ITALY TEL 39 049 9401150 FAX 39 049 9409140 E MAIL info shott it WEB...