Shott WP7000 Скачать руководство пользователя страница 13

E N  

 

 

Nome file:

File name:

7528002EN - ISTRUZIONI WP7.8000 - EN.docx 

Rev. 1 24/05/2016 

13-18 

 

6.4  Operating limits and environmental limits. 

 

Maximum water temperature: +35 [°C]. 

 

Minimum water temperature: +4 [°C]. 

6.5  Safety devices and signalling. 

  The product is equipped with a thermal protector. Following any thermal 

protector  operation,  check  the  causes  that  originated  the  product’s 
malfunction.  For  this  purpose,  please  consult  the  “Troubleshooting” 
section. 
The  product  shall  go  back  to  normal  operating  conditions  after  it  has 
cooled  down  (about  2÷3  hours)  and/or  the  caused  that  triggered  the 
thermal protector have been eliminated. 
6.6  Hazards and risks. 

  Attention  to  the  inlet/outlet  points  because  they  can  trap  parts  of  the 

body and/or hair and cause serious personal injuries and even death. 

  Pumps,  filters,  and  other  equipment/components  of  a  pool  filtration 

system  can  operate  under  pressure.  If  not  correctly  installed  they  can 
cause serious personal injuries and even death. 
The  product  is  powered  electrically,  so  maximum  diligence  in  its 
installation and maintenance is required, in order to avoid danger. Please 
pay particular attention to: 

 

the conditions of its power cord, which must not be damaged; 

 

do  not  use  the  product  without  its  pre-filter  basket  (Fig.  ?,  #  ?), 

otherwise the product may jam or be irreparably damaged; 

 

when  using  any  type  of  stop  valve  make  sure  the  line  is  completely 

open as the product must never run with valves closed. 

 

7.1  Description of the control/command devices. 

  Power plug with residual current device (RCD, when included). 

  Before turning on the product, always press the RESET button. Check 

power  plug  with  residual  current  device  operations  by  pressing  the TEST 
button (T). 

  Do  not  attempt  to  repair  or  open  the  power  plug  with  residual  current 

device;  in  the  event  of  fault,  replace  the  entire  power  plug  with  residual 
current device
 with the power cord
The  power  plug  with  residual  current  device  does  not  replace  mandatory 
electrical  safety  components:  the  electrical  system  must  meet  current 
international and/or national regulations. If necessary, contact specialised 
technicians. 

  The power plug with residual current device is an additional electrical safety component able to cut off a 

circuit in the event of fault. In order for it to work, it must: 

 

always be in the vertical position, 

 

always be clean and free of dust or water, 

 

be connected to a perfectly efficient ground line, 

 

check residual current device operations before turning on the product. 

  Checking residual current device operations. 

Plug the power plug with residual current device into the power outlet: 
1.  press  the  RESET  button  to  allow  the  product  to  be  turned  on:  the  light 
turns red. 
2.  press  the  TEST  (T)  button  to  test  residual  current  device  operations:  the 
light  turns  off  and  the  residual  current  device  cuts  off  electrical  power, 
therefore  the  product  cannot  be  turned  on  unless  the  RESET  button  is 
pressed again. 

  If the residual current device triggers (turns off the product) during product 

use, unplug the power plug with residual current device from the power outlet 

 

Fig. 24 

 

Fig. 25 

 

Fig. 26 

Pa

 

Fig. 27 

TEST (T)

RESET

Содержание WP7000

Страница 1: ...Nome file File name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 1 18 WP7000 WP8000 CUSTOMER MANUAL EN INSTALLATION MANUAL EN...

Страница 2: ...Nome file File name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 2 18...

Страница 3: ...onditions 8 5 3 Transport 8 5 4 Handling 8 5 5 Positioning 8 5 6 Connections and start up 10 Hose connection 11 Priming 11 5 7 Reinstallation and reuse 12 5 8 Demolition and disposal 12 Electric elect...

Страница 4: ...12 Mechanical seal a mechanical device is liable to isolating the two environments among which there is a shaft with a circular motion 13 Dry operation means the product s operation without water 14...

Страница 5: ...ts components and materials such as rotors bearings light bulbs o rings gaskets sponges cartridges etc that provided in the documentation that accompanies the product shall be observed iii The warrant...

Страница 6: ...ing on the product Attention to the moving parts Attention to the inlet outlet points because they can trap parts of the body and or hair and cause serious personal injuries and even death It is compu...

Страница 7: ...13 Power cord 14 Capacitor 15 Cover The hydraulic parts used for the building of the system which shall include the product modify the performance head and flowrate of the product WP7000 WP8000 Power...

Страница 8: ...perature 10 C 14 F to 60 C 140 F 5 3 Transport Handle the product with care to avoid damages The product is delivered suitably protected against transport damages However handle with care to avoid dam...

Страница 9: ...ming pool from which water is drawn Fig 11 Considering the following aspects is recommended Dimensions and position of hydraulic components Necessary clearance Fig 12 Power cord position Location of t...

Страница 10: ...Connections and start up The electrical system must meet current international and or national regulations The product must be connected to an power outlet equipped with a residual current device with...

Страница 11: ...inlet pipe hydraulic part to the IN rubber holder Fig 0 D and the outlet pipe to the OUT rubber holder Fig 0 E Fix the pipes hydraulic part with clips Fig 0 F Fig 20 Check the hydraulic pipe is as sh...

Страница 12: ...he end of its working life Therefore the user must take equipment to electronic and electro technical waste collection centres at the end of its working life or return it to the dealer when purchasing...

Страница 13: ...the control command devices Power plug with residual current device RCD when included Before turning on the product always press the RESET button Check power plug with residual current device operati...

Страница 14: ...Product components that due to their normal use suffer wear and or tear must be regularly replaced to ensure good product performance The following table shows the perishables and or consumables used...

Страница 15: ...s incorrectly installed Check correct gasket and o ring installation Contact specialised technicians 14 Water leak Fast connections or cover not tight Tighten fast connections and cover Contact specia...

Страница 16: ...or worn components as quickly as possible use only original spare parts Fig 30 WP7000 WP8000 1 XQ708I23 2a XQ710I23 2b XQ700I23 2c XQ709I23 3 XQ711I10 32 38 mm 4 XQ711I20 38 mm 5 XQ712I13 6 XQ713I23...

Страница 17: ...Nome file File name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 17 18...

Страница 18: ...name 7528002EN ISTRUZIONI WP7 8000 EN docx Rev 1 24 05 2016 18 18 SHOTT INTERNATIONAL S R L VIA DELLE PEZZE 35 35013 CITTADELLA PD ITALY TEL 39 049 9401150 FAX 39 049 9409140 E MAIL info shott it WEB...

Отзывы: