Replacing a nozzle
1
Unscrew two screws of the burner cover
and take the burner cover off.
2
Unscrew the nut and remove the Suction
Pipe from the fuel pump.
3
Unscrew the nut and remove the Return
Hose from the air vent valve.
Observations
• Be careful not to touch electrodes
4
Disconnect the red wire of overheat protec-
tion at the back of the burner base.
5
Unscrew three nuts and pull out the burner
unit.
6
Replace with a new nozzle by using the
provided nozzle spanner.
7
Tighten the nozzle using the nozzle span-
ner until the nozzle is fixed.
8
Put the burner unit back with three nuts re-
moved.
9
Put the red wire back.
10
Attach the return hose to the air vent valve
and the suction pipe to the fuel pump with
the nuts unscrewed.
11
Put the burner cover back with two screws
removed.
■
Replacing a fuse
1
Unscrew two screws and take the burner
cover off.
2
Replace with a new fuse on the board.
3
Put the burner cover back with two screws
removed.
2
3
Fuse
4
Nozzle
Nozzle Spanner