5
■
Inspection and cleaning of the flame monitor
The heater must be checked, if used for a
long time.
Observations
• When removing the flame monitor, hold it by its main assembly; do not pull out the cord.
1
Remove the burner cover and pull out the
flame monitor, and check whether or not its
lens is dirty/foul.
4-2. Periodic Inspection
2
If the lens is dirty/foul, please wipe the sur-
face of the lens with a soft cloth, etc. until it
becomes clear.
3
Restore the flame monitor, then please
surely fix with screws the burner cover.
Flame Monitor
Lens
Cotton Swab
Soft Cloth
Flame Monitor
■
Inspection of “dirt/dusts” on the main unit
1
Check whether or not dirt/dusts are on and
around the heater.
2
If dusts are found, please remove them
with a vacuum cleaner or wipe with a soft
cloth, etc.
Pull out
WARNING
• Never service the heater while it is burning, in operation, hot or plugged-in to avoid
any injury and/ or trouble.
• Before starting any service to avoid electric shock, please make sure the heater is shut
down and that the power cord is disconnected.
• When servicing the heater, please wear gloves to prevent possible injury.
CAUTION
How to replace the nozzle & fuse
Please ask the dealer from whom you
purchased the heater to check the heater
once every other season.