Inspecting the Tip-over switch
1
While the heater is operating, grasp the
handle and shake the heater up and down,
and from side to side.
2
Check if the tip-over switch has automati-
cally extinguished the flame.
3
If the tip-over switch did not activate, shut
down the heater and contact the dealer from
whom you purchased the heater.
4-1. Daily Inspection
■
Inspection of the tank inlet filter
1
Please remove the fuel cap and check if
dirt/dusts stick to the tank inlet filter.
Kerosene
Tank Inlet Filter
2
If there are any dirt/dusts, remove the filter
and wash it with fuel.
■
Inspection of the filter and drainage of water from the fuel tank.
1
Remove the suction pipe from the fuel
pump and the fuel tank.
Checking the filter element
2
If the filter is dirty, replace it with a new one.
3
Return the suction pipe to the fuel tank and
firmly secure.
3
Please restore the tank inlet filter, and tight-
en firmly the fuel cap.
Drainage of water from the fuel tank
1
Remove the fuel cap, take out the tank inlet
filter and insert a handy suction pump into
the tank.
2
Remove as much fuel as possible (with the
handy suction pump).
3
Restore the tank inlet filter and tighten firmly
the fuel cap.
4
Use a cloth, etc., to wipe off any kerosene or
water on the fuel tank.
Filter
Suction Pipe
Pull off
Pull up