7
2. Name and functions of sections
SE2
(Fig. 2-1)
SE1 , SEW
(Fig. 2-2)
Notice
When setting the specifications and functions of this instrument, connect terminals 13 and 14
for a power source first, then set them referring to “5.Operation flowchart” and “6. Setup”
before performing “3. Mounting” and “4. Wiring”.
(1) Power indicator (Green)
Lights when the power to the instrument is turned on.
(2) CH1 indicator (SE2 ) (Yellow)
Lights when CH1 input value and output value are
indicated.
(3) CH2 indicator (SE2 ) (Yellow)
Lights when CH2 input value and output value are
indicated.
(4) Input display (Red)
Indicates the input value during RUN mode.
Indicates characters of setting or adjustment item
during Setup and Adjustment mode.
(5) Output display (Red)
Indicates the output value (%) during RUN mode.
Indicates the set or adjusted value during Setup
and Adjustment mode.
(6) UP Key
(
)
Increases the numeric value, or switches the
selection items.
(7) DOWN Key
(
)
Decreases the numeric value, or switches the
selection items.
(8) MODE Key
(
)
Selects or switches groups, and registers the set
(or selected) value.
(9) SUB-MODE Key
Turns the displays ON again when they are in
OFF status.
(The UP, DOWN or MODE Key also turns the
displays ON again when they are in OFF status.)
(10) Console connector
By connecting to the USB communication cable
(CMB-001, sold separately), the following
operations can be conducted from an external
computer using the SWS-SE001M Console
software: Reading and setting of various set
values, Reading of input values and action status
(11) Light sensor
Automatically measures and controls brightness
of the Input and Output displays.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(10)
(8)
(9)
(11)
(1)
(4)
(5)
(6)
(7)
(8)
(9)
(11)