9. Specifications
9.1 Standard specifications
Model
: Console/Data logger
Name
: LMD-100
Mounting
: Flush
Setting
: Input system using membrane sheet key
Display (CH1, CH2)
PV display
: Red LED 4 digits, Character size, 14.3 (H) x 8.0 (W)mm
SV display
: Green LED 4 digits, Character size, 10.0 (H) x 5.6 (W)mm
CH display
: Yellow LED 2 digits, Character size, 10.0 (H) x 5.6 (W)mm
MEMO display : Yellow LED 1 digit, Character size, 10.0 (H) x 5.6 (W)mm
Time setting accuracy
: Within
0.5%
1 second
Clock
Time indication : 24-hour clock (00:00 to 24:00)
Error
: Within
60 seconds/month (at 25
ambient temperature)
Power failure guarantee: Backed up by lithium battery.
Lithium battery life: 10 years or more (at 20
ambient
temperature)
External memory device
Media
: Recommended CF cards: CF card included and also sold separately
by Shinko Techos Co., Ltd.
Type
I
(thickness 3.3mm)
Maximum capacity: 2GB
Format
: FAT16 (For commercially available CF card, it may be FAT32)
Writing method : Writing in a new file (Opens a new file every time logging starts,
and saves in it)
CF card memory usage: In the case of 2 controller units being connected, and
when logging all items with a logging cycle of 5 seconds, 1.7 to
2.0MB of the CF card can be used every 24 hours.
Others
: If logging data reaches 65,000 lines, the file is closed and saves
the data in a new file.
Note
: If a defective CF card is inserted, the reset function to prevent
malfunction is initiated, and the instrument reverts to warm-up
status.
Number of files: Max. 170
If the number of files exceeds 170, an error message is indicated
regardless of CF card remaining memory capacity.