6.4.1.
Brightness Adjustment
You can adjust the
brightness by clicking “
” or “
” on the scanner, or drag the cursor under the
camera preview to left (-) or right (+).
On
Scan Setting
interface, adjust brightness until you can see clear data and markers. Overbrightness
causes much noise on scan data.
Camera
window
Preview
display
Too bright (X)
Good (√)
Too dark (X)
6.4.2.
Optimal Distance Range
Distance color bar
Distance color on scanner
Red
Too close
Green
Optimal
Blue
Too Far
Red
Too close
Green
Optimal
Blue
Too Far
Scan mode
Resolution
Minimum
distance
Optimal distance
Maximum
distance
Standard scan
0.25~0.5mm
200mm
300mm
400mm
0.5~0.7mm
200mm
325mm
450mm
0.7~3.0mm
200mm
470mm
600mm
Body scan
\
370mm
470mm
570mm
Face scan
\
200mm
—
1500mm