Clean the back of the build platform
Step 3 Dry the surface of the build platform with a paper towel, and dry in a ventilated place before reuse.
Wipe the front of the build platform
Wipe the back of the build platform
5.3.
Cure Model
Use Fab Cure post-processing machine for the secondary curing treatment of the model. This machine uses the
principle that the photosensitive resin material will be cured and molded under the irradiation of a UV lamp with a
specific light wavelength.
Models after secondary curing can be stored for a long time without irritating human skin, and the
model’s
overall performance (smoothness, hardness, etc.) is better than ordinary models.
Step 1 Place the model into the curing box.
Wear disposable gloves, open the shading door of the curing box, uniformly place the cleaned model on the
center of the acrylic turntable of the curing box, close the shading door after placing.