51(56)
Picture 6-2
:
Daily Maintenance of V-belt
Motor 50Hz
18.5/22kW
30/37kW
45-55kW
New belt
15mm
14mm
15mm
Used belt (after be
used 6 months)
19mm
19mm
19mm
Motor 60Hz
18.5/22kW
30/37kW
45-55kW
New belt
18mm
17mm
16mm
Used belt (after be
used 6 months)
23mm
23mm
20mm
6.2.2 Adjust the V-belt
1) Take down the side plate on the control box that is located on the right side of
the machine.
2) Take out the storage bin; loose the position adjusting screws of the motor.
3) The tension of the belt could be altered by adjusting the distance between
motor and driving wheel. Tighten the screws after you finished the
adjustment.
4) Lockup the screw as figure 6-3 shows
5) Re-check belt tension after 20 to 30 hours operation under full load.
Picture 6-3
:
Adjust the V-belt
6.3 Lubrication
6.3.1 Lubricating Oils
Xin Chang Long: FX-00
FX-000
Содержание SG-3650E
Страница 1: ...SG 36E Standard Central Granulators Date Apr 2013 Version Ver A English...
Страница 2: ......
Страница 8: ...8 56...
Страница 28: ...28 56 2 4 Wiring Diagram 2 4 1 Main Circuit Picture 2 13 Main Circuit...
Страница 29: ...29 56 2 4 2 Control Circuit Picture 2 14 Control Circuit 1...
Страница 30: ...30 56 Picture 2 15 Control Circuit 2...
Страница 31: ...31 56 2 4 3 Electrical Components Layout Picture 2 16 Electrical Components Layout...