56(65)
5.
Trouble-shooting
5.1 Granulator Can Not Work
1) Check if the emergency stop has not been reset. If not, rotate the Button
anti-clockwise to reset it.
2) Check whether feed box is fully closed. If not, the machine could not be
started.
3) Check the motor's overload protector.
The overload protector in the electrical control box will work if the motor
overloads. Under that situation, (A) (the green pole) will sprout. Press the
Reset button (B) to reset it. Before startup again, check whether there is
any material in the granulator.
4) Check the space between blades.
Motor overload protection will trip and machine will stop if the blade is very
blunt or the space between blades is not correct.
Inspect blades, renew them or re-adjust blades space.
5.2 Stop Due to Other Reasons
Connection failure or looseness of safety switch can also cause shutdown
Note!
Do not disconnect to safety switch or control switch.
Содержание SG-24T
Страница 1: ...SG 24T Screenless Granulator Date Apr 2013 Version Ver B English...
Страница 2: ......
Страница 8: ...8 65...
Страница 25: ...25 65 2 3 3 Cutting Chamber and Blade Rest Picture 2 5 Cutting Chamber and Blade Rest...
Страница 29: ...29 65 2 4 Electrical Diagram 2 4 1 Main Circuit 400V Picture 2 9 Main Circuit 400V...
Страница 30: ...30 65 2 4 2 Control Circuit 400V Picture 2 10 Control Circuit 400V...
Страница 31: ...31 65 2 4 3 Electrical Components Layout 400V Picture 2 11 Electrical Components Layout 400V...
Страница 34: ...34 65 2 4 5 Main Circuit 230V Picture 2 12 Main Circuit 230V...
Страница 35: ...35 65 2 4 6 Control Circuit 230V Picture 2 13 Control Circuit 230V...
Страница 36: ...36 65 2 4 7 Electrical Components Layout 230V Picture 2 14 Electrical Components Layout 230V...
Страница 40: ...40 65 2 5 4 Proportional Valves Picture 2 18 Control Cabinet and Valve...
Страница 55: ...55 65 2 seized up machine stops Notice Mount sensor and ensure its space with big wheel to about 2 4mm...