once in the interface. Click on the ”Stop” button to stop.
6.7. Frequency Test Result
For frequency test result, see Figure 6-8 as follows:
Figure 6-8 Frequency Test Result
“Rev Pat”: PRBS code pattern of the receiving part in setup menu.
“Send Pat”: PRBS code pattern of the transmitting part in setup menu.
“Frequency“: actual frequency for receiving, with a unit of bit/s.
“Offset”: the offset between actual receiving frequency and ideal frequency (155.52Mb/s), with
a unit of ppm.
“Minimum“: the minimum value of the frequency measured in the interface, with a unit of bit/s.
“Maximum“: the maximum value of the frequency measured in the interface, with a unit of bit/s.
All results aren’t controlled by the shortcut key. Real-time reception and display are available
once in the interface. Click on the ”Stop” button to stop.
6.8. Tributary Test Result
For tributary test result interface, see Figure 6-9 as follows:
Figure 6-9 Tributary Test Result