DTA-SDH/155
Operating Manual
Shineway Technologies, Inc.
26
“Receive value of pointer“: receive in real time.
The ”Set” shortcut key can set up the input value or parameter for “Pointer type”, “NDF, “Setup
SS BITS” and “Transmit value of pointer“. “Receive value of pointer“ is not controlled by the shortcut
key and can receive in real time.
4.4. Pointer Sequences Test
For pointer sequences test, see Figure 4-5 as follows:
Figure 4-5 Pointer Sequences Test
The setup contents of “Pointer sequences” include: single-step reversed polarity, adding of one
pair at fixed period, loss of one at fixed eriod, pair of reversed polarity, single step, burst, 87-3, 87-3
plus, 87-3 minus, periodicity, periodicity plus and periodicity minus, with a default value of
“single-step reversed polarity”.
“INIT”: scope of setup 0-1638sec, with a minimum step length of 25ms and default value of 60.
“COOL”: scope of setup 0-1638sec, with a minimum step length of 25ms and default value of
30.
“T1”: scope of setup 0-107374182sec, with a minimum step length of 25ms, time type of
“millisecond, sec, minute, hour ” and default value of 1sec.
“T2”: scope of setup 0-65sec, with a minimum step length of 1ms, time type of “millisecond,
sec ” and default value of 2 millisecond.
“TADD”: scope of setup 0-255, with a default value of1.
“Pointer type”: AU, TU, with a default value of AU.
The “Set” shortcut key can set up all the input values or parameters. Once it is set up, “Insert
mode” changes to the current mode (insert sequence) instead of the original mode with a display on
the upper part of the screen. Then, the ”Insert” shortcut key can implement the insert.