![ShinewayTech DTA-SDH/155 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/shinewaytech/dta-sdh-155/dta-sdh-155_operating-manual_1257993030.webp)
DTA-SDH/155
Operating Manual
Shineway Technologies, Inc.
30
5. Function Test
Function test including: APS test, transparency test, TCM test, RTD test and tributary scan test.
See Figure 5 -1 as follows:
Figure 5 -1 Function Test
5.1. APS Test
For APS test, eee Figure 5 -2 as follows:
Figure 5 -2 APS Test
“Trigger”: MS-AIS, AU-AIS, TU-AIS, B1, and B2, with a default value of MS-AIS.
“Switching time “: with a unit of sec, real-time reception and display in the interface.
The “Set” shortcut key can set up all the input parameters of “Trigger”. Test starts immediately
once in the menu, with the display of results in “Switching time“ and “Status“ column. Pay attention
to the interlocking with ”Start” shortcut key.