24
Symptom
Possible Causes
Remedy
Starter motor does not
start
1. Battery is depleted
2. Battery is deteriorated
3. Fuse has blown
1. Recharge battery
2. Replace battery
3. Repair
Engine does not start
1. Close the fuel lever
2. Low fuel
3. Fuel is contaminated by
water or foreign material
4. Fuse has blown
1. Open the fuel lever
2. Supply fuel
3. Drain water from and clean the
fuel tank and inside of fuel filter
4. Repair
Engine stops
immediately
(Stops after
monitor lamp
lights up)
1. Low oil
2. Water temperature rise
3. Charging fault
4. Overspeed fault
1. Supply oil
2. Refer to "Usable Device
Capacities" and observe the
rated output
3. Repair
4. Repair
AC power is not output
1. Output switch is "OFF"
2. Fuse has blown
3. Inverter malfunction
1. Turn to "ON"
2. Repair
3. Repair
AC power is not output
(Overload
monitor lamp
flashes)
1. Output is stopped
because excessive
current is output due to
the excess or faulty
consumption current of
device using the
generator
2. Output is stopped due to
inverter overheating
1. Only use device with a current
capacity that is less than the
rated value
If doing this, turn the Output
switch to "OFF" and then "ON"
again to reset the generator
2. Stop the engine, and remove
any causes that are preventing
cooling such as foreign
material obstructing the
cooling air intake side of the
inverter. Allow the inverter to
cool before restarting the
engine
Device using the
generator does not
operate
(Weak output)
1 Current of Device using
the generator exceeds
the rated value
2. Idle Control switch is
turned to "ECO"
3. Different frequencies
1. Refer to "Usable Device
Capacities"
2. Turn the Idle Control switch to
"HIGH"
3. Adjust to the specified
frequency of device using the
generator
Engine does not stop
1. Stop solenoid
malfunction
2. Fuse has blown
1. Close the fuel lever to stop the
engine and repair
2. Close the fuel lever to stop the
engine and repair
Black or white smoke is
constantly emitted from
the muffler
1. Generator is overloaded
1. Observe the rated output
Refer to "Usable Device
Capacities"
Содержание IDG3100M
Страница 2: ......
Страница 28: ...25 2017 ...