 Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor 

performance, or severe engine damage and void the product warranty. Read and follow instructions in the Storage 

section of this manual.

a

ssembly

  

  WARNING   

Never perform maintenance or assembly procedures with engine 

running or serious personal injury may result.

blower

 

applIcatIon

Install Blower Pipes 

  1.  Align grooves in straight pipe with pegs on blower housing and 

slide pipe onto housing.

  2.  Turn straight pipe clockwise to lock into place.

  3.  Align grooves in fan head nozzle with pegs on straight pipe and 

slide fan head nozzle onto straight pipe.

  4.  Turn fan head nozzle clockwise to lock into place.

o

peratIon

9

Eng

lish

a

ssembly

  WARNING

Never perform maintenance or assembly procedures with engine 
running or serious personal injury may result.

bloWer applIcatIon

Install Blower Pipes 

Align grooves in straight pipe with pegs on blower housing and slide 
pipe onto housing.

Turn straight pipe clockwise to lock into place.

Align grooves in fan head nozzle with pegs on straight pipe and slide 
fan head nozzle onto straight pipe.

Turn fan head nozzle clockwise to lock into place.

1.

2.

3.

4.

o

peratIon

NOTICE:

 Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor 

performance, or severe engine damage and void the product warranty. Read and follow instructions in the Storage 
section of this manual.

fuel

  WARNING

Alternative fuels, such as E-20 (20% ethanol), E-85 (85% ethanol) or any fuels not meeting Shindaiwa requirements 
are

NOT

 approved for use in Shindaiwa 2-stroke gasoline engines.  Use of alternative fuels may cause performance 

problems, loss of power, overheating, fuel vapor lock, and unintended machine operation, including, but not limited 
to, improper clutch engagement.  Alternative fuels may also cause premature deterioration of fuel lines, gaskets, 
carburetors and other engine components.

  

 

WARNING

Moving parts can amputate fingers or cause severe injuries.  Keep hands, clothing and loose objects away from all 

openings.  Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop 

before removing obstructions, clearing debris, or servicing unit. Blower housing may contain shredder blades and 

other sharp edges that can cause serious injuries if touched, even if engine is off and blades are not moving.  Wear 

gloves to protect hands from sharp edges and hot surfaces. 

  

  WARNING

Operation of this equipment may create sparks that can start fires. This unit is equipped with a spark arrestor to 

prevent discharge of hot particles from the engine. Metal blade use on blade capable units also can create sparks if 

the blade strikes rocks, metal, or other hard objects. Contact local fire authorities for laws or regulations regarding 

fire prevention requirements.

fuel

  

 WARNING 

Alternative fuels, such as E15 (15% ethanol), E-85 (85% ethanol) or any fuels not meeting Shindaiwa requirements 

are NOT approved for use in Shindaiwa gasoline engines.  Use of alternative fuels may cause performance prob-

lems, loss of power, overheating, fuel vapor lock, and unintended machine operation, including, but not limited to, 

improper clutch engagement.  Alternative fuels may also cause premature deterioration of fuel lines, gaskets, carbu-

retors and other engine components.

Содержание EB212

Страница 1: ...and familiarize contents Always wear eye and when operating this unit WARNING Minimize the risk of injury to yourself and oth ers Read this manual and familiarize yourself with the contents Always we...

Страница 2: ...ant Information 3 International Symbols 3 Personal Condition and Safety Equipment 3 Equipment Check 6 Emission Control 6 Description 7 Contents 8 Assembly 9 Blower Application 9 Operation 9 Fuel 9 Sta...

Страница 3: ...act or condition which may lead to minor or moderate personal injury if not avoided NOTE This enclosed message provides tips for use care and maintenance of the unit IMPORTANT The enclosed message pro...

Страница 4: ...rements whenever you operate the unit Hand Protection Wear no slip heavy duty work gloves to improve your grip on the blower handle Gloves also reduce the trans mission of machine vibration to your ha...

Страница 5: ...on Repetitive Stress Injuries It is believed that overusing the muscles and tendons of the fingers hands arms and shoulders may cause soreness swelling numbness weakness and extreme pain in those area...

Страница 6: ...not be visible through openings WARNINg Check fuel system for leaks due to fuel tank damage especially if the unit is dropped If damage or leaks are found do not use unit otherwise serious personal in...

Страница 7: ...RTS ORDER ING instructions for specific information Hot Decal near muffler General Warning Decal located on top of blower housing English 1 2 3 4 5 6 7 8 10 9 11 65 Category I dB A Measured at 50 ft 1...

Страница 8: ...t lock design Contents 1 Power Head 1 Blower Pipe Assembly 1 Operator s Manual 1 Warranty Registration Card 8 English STOP SWITCH SLIDE SWITCH mounted on top of handle Push forward to start and run Sl...

Страница 9: ...requirements are NOT approved for use in Shindaiwa 2 stroke gasoline engines Use of alternative fuels may cause performance problems loss of power overheating fuel vapor lock and unintended machine o...

Страница 10: ...ol or 15 MTBE methyl tertiary butyl ether Gasoline containing methanol wood alcohol is NOT approved 2 Stroke Mixture Oil A 2 stroke engine oil meeting ISO L EGD ISO CD 13738 and J A S O M345 FD standa...

Страница 11: ...e required Protective Equipment and clothing Stop Switch Move stop switch button A away from the STOP position Throttle Position Move throttle position lever B midway between idle and full throttle po...

Страница 12: ...e your Shindaiwa dealer repair stop switch before using blower again 1 2 A F B A B E startInG Warm enGIne The starting procedure is the same as Cold Start except DO NOT close the choke Stop Switch Mov...

Страница 13: ...to perform a task Remember the higher the engine speed the louder the blower noise Minimize dust by using blower at lower speeds Keep debris on your property Be Smart be a good neighbor 1 2 3 4 6 B A...

Страница 14: ...it Allow unit to cool before performing service Wear gloves to protect hands from sharp edges and hot surfaces Maintenance component system maIntenance procedure reQ d skIll leVel daIly or before use...

Страница 15: ...Clean rag funnel and an approved fuel container WARNING Fuel is VERY flammable Use extreme care when mixing storing or handling Use a clean rag to remove loose dirt from around fuel cap and empty fue...

Страница 16: ...take grill above the fuel tank INTAKE GRILL 0 65 mm 0 026 in spark pluG Level 2 Tools required 3 4 in Spark Plug deep socket Feeler gauge IMPORTANT Use only BPMR 8Y spark plug otherwise severe engine...

Страница 17: ...ins Remove spark plug lead and spark plug Remove two upper 3 mm hex screws at recoil starter Remove engine cover five screws pull cover away from engine Loosely install spark plug to prevent dirt from...

Страница 18: ...TANT Never use a metal tool to scrape carbon from the exhaust port Do not scratch the cylinder or piston when cleaning the exhaust port Do not allow carbon particles to enter the cylinder 4 Inspect he...

Страница 19: ...ed RPM should be set to specifications found on Specifications page of this manual 7 Check idle speed and reset if necessary 18 English Cylinder Exhaust Port Level 3 IMPORTANT The cylinder exhaust por...

Страница 20: ...e r e v o C l e u f h t i w d e l u o F e v i t c e f e d g u l P n i 6 2 0 0 m m 5 6 o t t s u j d A e c a l p e r r o n a e l C e c a l p e r r o n a e l C g u l p e c a l p e R s n u r e n i g n E...

Страница 21: ...position 3 Remove accumulation of grease oil dirt and debris from exterior of unit 4 Perform all periodic lubrication and services that are required 5 Tighten all screws and nuts 6 Drain fuel tank co...

Страница 22: ...l Ratio 50 1 two stroke air cooled engine oil Gasoline Use 89 Octane unleaded Do not use fuel containing methyl alcohol more than 10 ethyl alcohol or 15 MTBE Do not use alternative fuels such as E 15...

Страница 23: ...or have questions concerning Shindaiwa s Warranty Statement you can contact our Consumer Product Support Department at 1 800 673 1558 or contact us through the web at WWW SHINDAIWA COM PRodUCT WARRAN...

Страница 24: ...e operator s manual is the customer s responsibility Failures due to improper set up pre delivery service or repair service by anyone other than authorized Shindaiwa servicing dealer during the warran...

Страница 25: ...t SORE was designed built and equipped to conform with applicable EPA and C A R B emissions standards and that your equipment SORE is free from defects in material and workmanship that would cause it...

Страница 26: ...26 notes...

Страница 27: ...27 Power Blower Operator s Manual notes...

Страница 28: ...lable on WWW SHINDAIWA COM When presenting your unit for Warranty service repairs proof of purchase is required Consumer Product Support If you require assistance or have questions concerning the appl...

Отзывы: