Shindaiwa EB212 Скачать руководство пользователя страница 1

English................1
Spanish.........SP_1
French..........FR_1

SHINDAIWA OWNER’S/OPERATOR’S MANUAL

EB212 BLOWER

Part Number 82051 Rev. 6/08

Minimize the risk of injury to yourself and others!

Read this manual and familiarize yourself with the 

contents.  Always wear eye and hearing protection 

when operating this unit.

WARNING!

Minimize the risk of injury to yourself and oth-

ers!  Read this manual and familiarize yourself 

with the contents.  Always wear eye and hearing 

protection when operating this unit.

 

WARNING!

SHINDAIWA OWNER’S/OPERATOR’S MANUAL

EB212 BLOWER 

X7531138500

11/12

Содержание EB212

Страница 1: ...and familiarize contents Always wear eye and when operating this unit WARNING Minimize the risk of injury to yourself and oth ers Read this manual and familiarize yourself with the contents Always we...

Страница 2: ...ant Information 3 International Symbols 3 Personal Condition and Safety Equipment 3 Equipment Check 6 Emission Control 6 Description 7 Contents 8 Assembly 9 Blower Application 9 Operation 9 Fuel 9 Sta...

Страница 3: ...act or condition which may lead to minor or moderate personal injury if not avoided NOTE This enclosed message provides tips for use care and maintenance of the unit IMPORTANT The enclosed message pro...

Страница 4: ...rements whenever you operate the unit Hand Protection Wear no slip heavy duty work gloves to improve your grip on the blower handle Gloves also reduce the trans mission of machine vibration to your ha...

Страница 5: ...on Repetitive Stress Injuries It is believed that overusing the muscles and tendons of the fingers hands arms and shoulders may cause soreness swelling numbness weakness and extreme pain in those area...

Страница 6: ...not be visible through openings WARNINg Check fuel system for leaks due to fuel tank damage especially if the unit is dropped If damage or leaks are found do not use unit otherwise serious personal in...

Страница 7: ...RTS ORDER ING instructions for specific information Hot Decal near muffler General Warning Decal located on top of blower housing English 1 2 3 4 5 6 7 8 10 9 11 65 Category I dB A Measured at 50 ft 1...

Страница 8: ...t lock design Contents 1 Power Head 1 Blower Pipe Assembly 1 Operator s Manual 1 Warranty Registration Card 8 English STOP SWITCH SLIDE SWITCH mounted on top of handle Push forward to start and run Sl...

Страница 9: ...requirements are NOT approved for use in Shindaiwa 2 stroke gasoline engines Use of alternative fuels may cause performance problems loss of power overheating fuel vapor lock and unintended machine o...

Страница 10: ...ol or 15 MTBE methyl tertiary butyl ether Gasoline containing methanol wood alcohol is NOT approved 2 Stroke Mixture Oil A 2 stroke engine oil meeting ISO L EGD ISO CD 13738 and J A S O M345 FD standa...

Страница 11: ...e required Protective Equipment and clothing Stop Switch Move stop switch button A away from the STOP position Throttle Position Move throttle position lever B midway between idle and full throttle po...

Страница 12: ...e your Shindaiwa dealer repair stop switch before using blower again 1 2 A F B A B E startInG Warm enGIne The starting procedure is the same as Cold Start except DO NOT close the choke Stop Switch Mov...

Страница 13: ...to perform a task Remember the higher the engine speed the louder the blower noise Minimize dust by using blower at lower speeds Keep debris on your property Be Smart be a good neighbor 1 2 3 4 6 B A...

Страница 14: ...it Allow unit to cool before performing service Wear gloves to protect hands from sharp edges and hot surfaces Maintenance component system maIntenance procedure reQ d skIll leVel daIly or before use...

Страница 15: ...Clean rag funnel and an approved fuel container WARNING Fuel is VERY flammable Use extreme care when mixing storing or handling Use a clean rag to remove loose dirt from around fuel cap and empty fue...

Страница 16: ...take grill above the fuel tank INTAKE GRILL 0 65 mm 0 026 in spark pluG Level 2 Tools required 3 4 in Spark Plug deep socket Feeler gauge IMPORTANT Use only BPMR 8Y spark plug otherwise severe engine...

Страница 17: ...ins Remove spark plug lead and spark plug Remove two upper 3 mm hex screws at recoil starter Remove engine cover five screws pull cover away from engine Loosely install spark plug to prevent dirt from...

Страница 18: ...TANT Never use a metal tool to scrape carbon from the exhaust port Do not scratch the cylinder or piston when cleaning the exhaust port Do not allow carbon particles to enter the cylinder 4 Inspect he...

Страница 19: ...ed RPM should be set to specifications found on Specifications page of this manual 7 Check idle speed and reset if necessary 18 English Cylinder Exhaust Port Level 3 IMPORTANT The cylinder exhaust por...

Страница 20: ...e r e v o C l e u f h t i w d e l u o F e v i t c e f e d g u l P n i 6 2 0 0 m m 5 6 o t t s u j d A e c a l p e r r o n a e l C e c a l p e r r o n a e l C g u l p e c a l p e R s n u r e n i g n E...

Страница 21: ...position 3 Remove accumulation of grease oil dirt and debris from exterior of unit 4 Perform all periodic lubrication and services that are required 5 Tighten all screws and nuts 6 Drain fuel tank co...

Страница 22: ...l Ratio 50 1 two stroke air cooled engine oil Gasoline Use 89 Octane unleaded Do not use fuel containing methyl alcohol more than 10 ethyl alcohol or 15 MTBE Do not use alternative fuels such as E 15...

Страница 23: ...or have questions concerning Shindaiwa s Warranty Statement you can contact our Consumer Product Support Department at 1 800 673 1558 or contact us through the web at WWW SHINDAIWA COM PRodUCT WARRAN...

Страница 24: ...e operator s manual is the customer s responsibility Failures due to improper set up pre delivery service or repair service by anyone other than authorized Shindaiwa servicing dealer during the warran...

Страница 25: ...t SORE was designed built and equipped to conform with applicable EPA and C A R B emissions standards and that your equipment SORE is free from defects in material and workmanship that would cause it...

Страница 26: ...26 notes...

Страница 27: ...27 Power Blower Operator s Manual notes...

Страница 28: ...lable on WWW SHINDAIWA COM When presenting your unit for Warranty service repairs proof of purchase is required Consumer Product Support If you require assistance or have questions concerning the appl...

Отзывы: