22
Fuel Inlet
Fuel Strainer
Fuel Cover
Tank Cap
If LLC gets on skin or clothing, wash with water immediately.
LLC is flammable. Store in a location where flame is prohibited and it cannot be accessed by
children.
Engine coolant could leak if the radiator is not completely tightened or there is a gap in the seating
face. Always be sure to securely tighten the radiator cap.
Do not add engine coolant past the FULL level line of the coolant sub-tank.
(3) Coolant Capacity
Total Coolant Capacity
2.3 (0.3) gal
.
Value in parenthesis is the sub-tank capacity.
8-3. Checking the Fuel
CAUTION : FIRE
This generator uses diesel fuel. Always be sure to stop the engine and not
bring flames close when inspecting fuel or refueling. Wait until the engine has
cooled before performing such procedures.
If fuel spills, always be sure to open the spill containment drain valve and
drain off the spilled fuel.
(
Refer to section “
10. Inspection/Maintenance (9) Flushing Liquid in Spill
Containment
”.)
Check if there is a sufficient amount of fuel and add fuel if insufficient.
The fuel meter on the control panel will only display the fuel level for the internal fuel tank.
Be sure to close the cap tightly after refueling.
< Note >
Use Diesel fuel, ASTM D975 No.2-D, S15. Engine is designed
to operate on Ultra Low Sulfur Diesel Fuel only. Use of any
other fuel may result in engine no longer operating in
compliance with emissions requirements.
The fuel supply pump, injectors and other parts of the fuel
system and engine can be damaged if any fuel or fuel additives
are used other than those specifically recommended by the
engine manufacturer.
Always be sure to use the fuel strainer attached to the fuel inlet.
Carefully add fuel until the tank is full.
Always be sure to wipe up any spilled fuel.
8-4. Checking the Spill Containment
CAUTION : FIRE
If fuel or oil leaks, repair the leaking location before operating.
Open the check door and check the inside of the spill containment. Flush out any accumulated
liquid.
Refer to section “
10. Inspection/Maintenance (9) Flushing Liquid in Spill
Containment
” for flushing procedures.