39
Radiator Cap Cover
Radiator Cap
Inlet
Radiator Plate
(7) Change Coolant
Remove the radiator plate first and open
the radiator cap cover.
Remove the radiator cap.
Remove the Coolant Drain Plug.
After draining finishes, tighten the Coolant
Drain Plug.
Drain the sub tank stay and drain coolant in the
sub
tank.
Reinstall the sub tank and fill coolant up to
MAX level.
Fill coolant into radiator up as far as the
water inlet level.
Tighten the radiator cap.
Close the radiator cap cover and
Reinstall the radiator plate.
< Note >
Refer Coolant to
『
8-2. Checking Coolant
/ Water
』
.
Change
2 years or 1000 hours
2
3
4
5
6
7
9
1
8
Coolant Drain
MIN
MAX
Over Flow
Hose
Sub Tank