29
8-5. Checking for Fuel, Oil and Coolant Leaks
CAUTION : FIRE
Do not use this equipment when leak is found, and repair the leaking location
before operating.
Open the check door and check for fuel, oil and coolant leakage from fuel piping connections
and similar locations.
8-6. Checking the Battery
CAUTION : EYE/SKIN INJURY
Wear rubber gloves and other protective wear to protect eyes, skin and
clothing from the battery fluid which contains diluted sulfuric acid. If the
battery fluid contacts eyes or skin, wash out immediately with a large amount
of water. Be sure to receive medical treatment, especially if the fluid contacts
the eyes.
CAUTION : EXPLOSION
Never use or recharge the battery if the fluid level is below the minimum
level.
Do not create sparks or bring flame near the battery as it generates
flammable gas.
Check the fluid level, and add distilled water when it is near the lower level until it
reaches the upper level.
Check the terminals for looseness and tighten if
loose.
< NOTE >
It is necessary to recharge the battery when the specific
gravity of the battery fluid is 1.23 or less. Request the
authorized distributor where the generator was purchased
to recharge the battery.