Shimadzu OPESCOPE ACTENO Скачать руководство пользователя страница 8

Conducting Examinations 2

 Instruction Manual 3.9 Fluoroscopy, 3.10 Changing I.I. Field Size (Zooming-up Images), 3.11.4 Setting the Beam Hardening Filter

M516-E044

C

on

du

cti

ng

 E

xa

m

in

at

io

ns

 2

If a switching state is registered 

using Smart C memory, the 
settings can be configured with 

one click after APR switching.

The initial values will be set if the 
APR is switched during a study.

Memo

Changing Fluoroscopy Conditions

Increases the tube 

voltage

Changing the tube voltage.

Selecting the I.I. field size

Change the Dose

Change the Pulse rate

Changing the filter.

Auto

Manual

Switches the 

X-ray adjustment 

mode.

The filter is changed each time 

 is 

pressed.

Display

Material (Applications)

Filter 1

Cu0.1 mm (The limbs, etc.)

Filter 2

Cu0.2 mm (Trunk, vertebral body, etc.)

Filter 3

Cu0.3 mm (Chest, abdomen, etc.)

NONE

No filter

Display

Continuous

Continuous 

fluoroscopy.

▼  ▲

15 fps

Pulse 

fluoroscopy

▼  ▲

10 fps

Pulse 

fluoroscopy

▼  ▲

7.5 fps

Pulse 

fluoroscopy

▼  ▲

3.75 fps

Pulse 

fluoroscopy

Reduces the tube 

voltage

* Only valid when the X-ray adjustment mode is 

set to manual.

Displays the fluoroscopy mode selection screen.

Displays the APR selection screen.

Select the APR

Field size

with 9” I.I.

with 6” I.I.

Button (Color)

Normal

9"

6"

 (Gray)

Zoomed

6"

4"

 (Blue)

Содержание OPESCOPE ACTENO

Страница 1: ...art C Memory Frame Memory Loop Memory Apply power only to the C arm Conducting Examinations 1 2 Starting an Examination Selecting the APR Conducting Examinations 2 3 Fluoroscopy Adjusting Image Changi...

Страница 2: ...C arm cart s brake applied Operate the brake Are the monitor cart s brakes applied Operate the brake Visual aural inspection Is the operating noise normal Notify Is any error message displayed on the...

Страница 3: ...wn 8 1 2 4 6 7 Power switch Take the power plug out of the outlet 5 Shut down the system from the reference monitor 3 2 Main panel 3 Front of the monitor cart Back of the monitor cart C arm M516 E044...

Страница 4: ...ment C arm slide motion About the scales The zero on each scale is the C arm s home position fixed position Starting up and Shutting down the System Instruction Manual 3 6 Positioning Handle Handle Ha...

Страница 5: ...he LAN cable to the back of the monitor cart Temporary data information can be changed afterward in the Today tab or the All tab in the Study List window The patient information of images acquired in...

Страница 6: ...ic Screen APR Selection Screen Immediate Selecting the APR Immediate Select the APR 2 The basic screen is displayed and the parameters registered in the APR are loaded 1 The APR selection screen Immed...

Страница 7: ...splayed at the top right of the LCD display Resets the image brightness setting to the default value Parallel compensating filter open close Parallel compensating filter rotation Octagonal collimator...

Страница 8: ...the Dose Change the Pulse rate Changing the filter Auto Manual Switches the X ray adjustment mode The filter is changed each time is pressed Display Material Applications Filter 1 Cu0 1 mm The limbs...

Страница 9: ...r foot from the foot switch during irradiation will end X ray irradiation partway through and stop radiography Depress the right foot switch 3 During X ray irradiation the radiography image is display...

Страница 10: ...mators Beam hardening filter Image rotation and inversion I I field size Storing Calling Up Basic screen 1 Press Save You can save the currently displayed images If any condition is changed from the s...

Отзывы: