Operating manual: Mobile speciality pump CHIEMSEE
SHG
S
PECHTENHAUSER
H
OCHWASSER
-
UND
G
EWÄSSERSCHUTZ
G
MB
H
Gewerbestraße 3, D-86875 Waal, Germany
www.spechtenhauser.de
Tel.:
+49 (0)8246.9695-20
Fax:
+49 (0)8246.9695-24
0119BACHE28
11
Danger:
The PE intake nozzles (CHIEMSEE H/CHIEMSEE EX: stainless steel nozzle) on the
inlet side are used to protect the impeller from contact. The pumps themselves may
not be operated without the appropriate contact protection.
4.
Mount a dimensionally stable spiral pressure hose with matching coupling to the outlet
side of the pump. A suitable fire hose can now be connected to this spiral hose. Lay
this at a suitable drain or collection tank. The end of the pressure hose must be ade-
quately secured against impact. The fire hose should be laid without kinks where pos-
sible to achieve an optimum pumping power. It is strongly recommended that you use
the optional dimensionally stable spiral pressure hose for the first 3-5 m.
Danger:
Ensure that the pressure hose end is adequately secured and fixed. Otherwise, there
is the risk of the hose end being hit when switching on the pump.
5.
If the pump is to be lowered into a shaft, attach a suitable length of rope to the eyelet
provided for this purpose.
Caution:
To lower the pump only the designated abseiling eyelet is used. Under no circum-
stances should the pump be lowered to the mains cable or the connected hoses.
6.
Lower the pump on this rope into the liquid.
Danger from suspended loads:
When lowering the pump, ensure that no-one is under the pump in the shaft.
7.
Make sure that the pump is standing safely.
8.
Ensure that the pump is switched off. To do this, the red push-button on the motor
protection plug has to be pressed. Plug the motor protection plug into a socket that is
fused via a residual current device (RCD) with a rated residual current of no more than
30 mA. Each plug-in connection (socket, generator, etc..) must be fused with an over-
current protective device with 16 Ampere. The overcurrent protective device must at
least have tripping characteristic B, characteristic C is recommended.
Danger from electric shock:
Ensure that the network socket at the network socket connection is dry. Never carry
out changes on the plug! The plug must be FI-secured (residual current circuit
breaker).
9.
Now check the phase position. If the red light "phase control" on the motor protection
plug is lit, the rotating field has to be changed. Remove the plug from the socket and
turn the reversing contact on the motor protection switch using an appropriate screw-
driver. Never modify the socket for this purpose! Insert the motor protection plug into
the socket again. The red light "wrong phase position" should no longer be lit.
10. Switch the pump on by pressing the green power button on the motor protection plug.
The pump should now pump with the defined pumping performance.
Caution:
The plug and the motor protection switch must be easy to access during operation of
the pump. They must always be supervised, so that they cannot be plugged in or
unplugged or acknowledged, erroneously or accidentally.
11. Switch the pump off again by pressing the red button, as soon as the water level has
sunk so far that the pump is taking in air.