4.1 Explanation of the standard motor protection plug
With the exception of CHIEMSEE EX, all versions of the CHIEMSEE are fitted with the
standard motor protection plug (see Image 1). The motor protec-
tion switch is set in the factory and may not be changed. Incorrect
setting of the motor protection switch can lead to malfunctions or
damage to the motor or pump.
Factory setting of the motor protection switch:
CHIEMSEE A: 9.5 A
CHIEMSEE B: 9.0 A
Section 4.11 of this operating manual is to be observed with
CHIEMSEE EX.
Before the standard motor protection plug is inserted into an FI-
secured safety socket for operation of the pump, it is to be en-
sured that the red push-button on the motor protection plug is
pressed, in order to rule out accidental starting of the pump.
Red control lamp
If the red control lamp "Falsche Phasenlage" (wrong phase po-
sition) lights up when inserting the motor protection plug, the ro-
tating field has to be changed. Remove the plug from the socket
and turn the reversing contact on the motor protection switch us-
ing an appropriate screwdriver. Never modify the socket for this
purpose! Insert the motor protection plug into the socket again.
The red light "wrong phase position" should no longer be lit.
Green push-button
To start the pump, the green push-button on the motor protection switch is to be pressed.
Red push-button
To switch off the pump, the red push-button on the motor protection plug is to be pressed.
4.2 Operating the pump
For safe working on and with the pump, the wearing of safety shoes and safety gloves is
recommended, in order to prevent injury from crushing or cutting.
Each time when using the pump, also ensure the following points:
1.
Before using the pump, it must be checked for damage to the plug, cable and motor
protection housing.
2.
Transport the pump to the place of use.
Caution:
Always transport the pump with the handles pro-
vided for this purpose only.
3.
Mount the intake nozzle (handle protection) with the
opening upwards on the coupling on the inlet side
of the pump (see Image 2.1). This avoids the suc-
tion of stones or other hard objects from the ground.
On the other hand, a sufficient water level remains
in this way, in order to carry out low-level pumping
after shutting off the pump without additional filling
of the pump.
Caution:
Before operating the pump, check that the impeller can move freely only when the
pump is switched off and the power supply disconnected.
Image 2.1: CHIEMSEE with
mounted intake nozzle