![Sherwood Scuba SAGE Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/sherwood-scuba/sage/sage_manual_1256682044.webp)
44
SAGE MANUAL
© Pelagic, 2017
Doc. No. 12-7864-r06 (8/21/17)
DELAYED VIOLATION 3 (DV 3)
If you descend deeper than the maximum functional depth*, the audible alarm will sound. Also, the up arrows, and TOO DEEP GO UP message will
flash. Only dashes will display for Current Depth signifying that you are too deep.
* The maximum functional depth (AIR/NX or GAUGE = 330 ft / 100 m) is the depth at which the Sage can properly perform calculations or provide
accurate display information.
Upon ascending above the maximum functional depth, current depth will be restored. However, the log for that dive will display dashes for max
depth.
---
2978
PSI
FT
0:24
DIVE TIME
TOO DEEP
GO UP!
GAS 1
AIR
flashing
VIOLATION GAUGE MODE (VGM) DURING A DIVE
During AIR/NX mode dives, operation will enter VGM when Decompression requires a Stop Depth greater than 70 ft (21 m). Operation would
then continue in VGM during the remainder of that dive and for 24 hours after surfacing. VGM turns the Sage into a digital instrument without any
decompression or oxygen related calculations or displays. Upon activation of VGM, the audible alarm will sound. The message VIOLATION GO UP
with up arrows will flash. After the audible alarm becomes silent (10 seconds), the Safe Minutes (No Decompression) and N2 Bar Graph will not
display for the rest of the dive.
245
1056
PSI
FT
1:34
DIVE TIME
VIOLATION
GO UP!
flashing
HIGH PO2
Warning >> at Alarm Set Point value minus .20
Alarm >> at Set Point value, except in Deco then at >1.60 only
Warning
When PO2 (partial pressure of oxygen) increases to the Warning level; the audible alarm sounds and the PO2 value will flash (in place of
DIVE TIME) until the audible alarm is silenced.
127
21
1.20
FT
PO2
1056
NX 32
GAS 1
PSI
HIGH PO2
flashing
flashing
Содержание SAGE
Страница 1: ...Pelagic 2017 Doc No 12 7864 r06 8 21 17 DIVE COMPUTER MANUAL...
Страница 5: ...5 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 GETTING STARTED...
Страница 12: ...12 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 DIVE FEATURES...
Страница 17: ...17 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 AIR NX SURFACE MODE...
Страница 37: ...37 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 AIR NX DIVE OPERATION...
Страница 46: ...46 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 GAUGE OPERATION MODE...
Страница 51: ...51 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 COMPASS MODE...
Страница 57: ...57 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 REFERENCE...
Страница 63: ...63 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 NOTES...
Страница 64: ...64 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 Sage DIVE COMPUTER MANUAL...