CONDITIONAL VIOLATION (CV)
Upon ascent above the required Decompression (deco) Stop depth, operation will enter Conditional Violation during which time no off gassing
credit will be given. The Audible alarm will sound. Additionally, the full N2 Bar Graph, down arrows, and DOWN message will flash until the au-
dible alarm is silenced, then the N2 Bar Graph will be solid.
• The down arrows continue to flash until descending below the required Stop Depth (within stop zone), then the DECO STOP graphic will be on
solid.
• If you descend deeper than the required Decompression Stop before 5 minutes elapse, Decompression operation will continue with no off gassing
credit given for time above the Stop. Instead, for each minute above the Stop 1½ minutes of penalty time will be added to the required Stop Time.
• The added penalty (decompression) time will have to be worked off before obtaining off gassing credit.
• Once the penalty time is worked off, and off gassing credit begins, required Decompression Stop Depths and Time will decrease toward zero. The
N2 Bar Graph will recede into the No Decompression zone, and operation will revert to No Decompression mode.
1123
PSI
PSI
TAT
0:09
GAS 1
AIR
15
FT
DOWN
20
FT
2
MIN
missed
stop
depth
stop time
DELAYED VIOLATION 1 (DV 1)
If you remain shallower than a Deco Stop Depth for more than 5 minutes, operation will enter DV1* which is a continuation of CV with penalty time
still being added. Again, the audible alarm will sound and the full N2 Bar Graph will flash until it is silenced. ALT screens are accessed and appear
similar to Deco ALT screens.
*The difference is that 5 minutes after surfacing from the dive, operation will now enter Violation Gauge Mode.
• Down arrows and the DOWN message continues to flash until descending below the required Stop Depth, then the full stop graphic will be on
solid.
• If the DV1 status is ignored, the Sage will enter DV1 Surface mode for 5 minutes upon surfacing from the dive. Down arrows and Deco Stop
depth/time will flash with the DOWN message. After 5 minutes on the surface in DV1 mode, the unit will enter VGM (Violation Gauge Mode).
15
913
AIR
GAS 1
PSI
FT
0:12
TAT
20
FT
3
MIN
DOWN
missed
stop
depth
time required at
missed stop
DV1 DIVE MAIN
0
954
PSI
FT
0:12
TAT
20
FT
8
MIN
DOWN
GAS 1
AIR
DV1 <5 MIN ON SURFACE
DELAYED VIOLATION 2 (DV 2)
If the calculated Decompression obligation requires a Stop Depth between 18 m (60 ft) and 21 m (70 ft), operation will enter DV2. The audible
alarm will sound. Additionally, the full N2 Bar Graph will flash until the audible is silenced.
• Up arrows flash if 3 m (10 ft) deeper than the required Stop Depth.
• Once within 3m (10 ft) of and below the required Stop Depth, the DECO STOP message will be displayed solid.
76
1085
PSI
FT
0:30
TAT
VIOLATION
60
FT
8
MIN
GAS 1
AIR
Deco Stop depth
60 -70 ft (18 - 21 m)
Содержание SAGE
Страница 1: ...Pelagic 2017 Doc No 12 7864 r06 8 21 17 DIVE COMPUTER MANUAL...
Страница 5: ...5 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 GETTING STARTED...
Страница 12: ...12 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 DIVE FEATURES...
Страница 17: ...17 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 AIR NX SURFACE MODE...
Страница 37: ...37 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 AIR NX DIVE OPERATION...
Страница 46: ...46 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 GAUGE OPERATION MODE...
Страница 51: ...51 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 COMPASS MODE...
Страница 57: ...57 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 REFERENCE...
Страница 63: ...63 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 NOTES...
Страница 64: ...64 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 Sage DIVE COMPUTER MANUAL...