ALGORITHM

The algorithm is based upon Haldane’s theory using maximum allowable nitrogen levels developed by Merrill Spencer. Repetitive diving control is 

based upon experiments designed and conducted by Dr. Ray Rogers and Dr. Michael Powell in 1987. Diving Science and Technology® (DSAT), a 

corporate affiliate of PADI®, commissioned these experiments. To create even greater margins of safety with respect to decompression, a Conserva-

tive Factor as well as No Decompression Deep and Safety Stops can be included for No Decompression dives.

CONSERVATIVE FACTOR

When the CF is set On, the dive time remaining, No Decompression/O2 MIN, which are based on the algorithm and used for N2/O2 calculations 

and displays relating to Plan Mode, will be reduced to the values available at the altitude level that is 3,000 (915 m) higher than the actual altitude 

at activation. Refer to the charts in the back of this manual for dive times.

DS (DEEP STOP)

When the DS selection is set ON, it will trigger after descending deeper than 80 ft (24 m). The Sage then calculates (continually updating) a Stop 

Depth equal to ½ the Max Depth.

 

NOTE: The Deep Stop feature only works in DIVE mode while within No Decompression times.

•  While 10 ft (3m) deeper than the calculated Deep Stop, you will be able to access a Deep Stop Preview screen that will display the current calcu-

lated Deep Stop Depth/Time.

 

•  Upon initial ascent to within 10 ft (3 m) below the calculated Stop Depth, a Deep Stop screen displaying a Stop Depth at ½ the Max Depth will 

appear with a countdown timer beginning at 2:00 (min:sec) and counting down to 0:00. If you descend 10 ft (3 m) below, or ascend 10 ft (3 m) 

above, the calculated Stop Depth for 10 seconds during the countdown, the No Decompression Main will replace the Deep Stop Main display 

and the Deep Stop feature will be disabled for the remainder of that dive. There is no penalty if the Deep Stop is ignored.

•  In the event that you enter Decompression, exceed 190 ft (57 m), or a High O2 SAT (Oxygen Saturation) condition, ≥ 80%, occurs, the Deep 

Stop will be disabled for the remainder of that dive.

• The Deep Stop is disabled during a High PO2 Alarm condition, ≥ set point.

SS (SAFETY STOP)

Upon ascent to the Safety Stop depth 20 ft (6 m) for 1 second on a No Decompression dive in which depth exceeded 30 ft (9 m) for 1 second, a 

beep will sound and a Safety Stop at the depth 20 ft (6 m) will appear on the NX/AIR Dive Main display with a countdown beginning at the Safety 

Stop time 3:00 (min:sec) and counting down to 0:00.

•  In the event that you descend 10 ft (3 m) deeper than the Stop Depth for 10 seconds during the countdown, or the countdown reaches 0:00, the 

No Decompression Main screen will replace the Safety Stop Main screen which will reappear upon ascent to 20 ft (6 m), the Safety Stop depth, 

for 1 second.

•  In the event that you enter Decompression during the dive, complete the Decompression obligation, then descend below 30 ft (9 m); the Safety 

Stop Main will appear again upon ascent to the Safety Stop depth, 20 ft (6 m), for 1 second.

•  If you ascend to 3 ft (0.9 m) of the surface for 1 second, the Safety Stop will be canceled for the remainder of that dive.

• There is no penalty if you surface prior to completing the Safety Stop or choose to ignore it.

LOW BATTERY WHILE ON THE SURFACE

 WARNING:  Change the battery before diving if your Sage indicates the Battery Low Warning or Alarm.

Warning Level

• The Sage functions continue but but screen brightness is limited to 60% max.

• The Battery icon and LOW BATTERY message appears amber.

1:39

845

PSI

SURF

TIME

LOW BATTERY

GAS 1

NX 32

Содержание SAGE

Страница 1: ...Pelagic 2017 Doc No 12 7864 r06 8 21 17 DIVE COMPUTER MANUAL...

Страница 2: ...9 A HOUR FORMAT 29 B SET HOUR 30 C DATE FORMAT 30 D SET DATE 31 5 BLUETOOTH 32 6 SET AUTO DIM 32 MODE 33 MY INFO 33 DC DIVE COMPUTER INFO 33 PLAN 34 LOG 35 HISTORY 36 AIR NX DIVE OPERATION 37 INITIATI...

Страница 3: ...is NOT for use by military and commercial divers It should NOT be utilized for any competitive or repetitive square wave or decompression diving as it is intended solely for recreational use As with a...

Страница 4: ...o event will Sherwood Scuba its distributors or retailers be held liable for any personal injuries resulting from its operation or for any other damages whether direct indirect incidental or consequen...

Страница 5: ...5 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 GETTING STARTED...

Страница 6: ...aced or recharged before use when the low battery warning is displayed on the dive main screen Keep in mind that the Sage s color screen is the biggest draw of power Using full brightness settings wil...

Страница 7: ...ed end of the cover into the groove at the base of the threads Insert a new or rechargeable battery positive side first into the battery compartment with the negative end facing out Ensure that the ba...

Страница 8: ...elease from the console Assembly Visually inspect the fittings and connection O ring for damage corrosion or deterioration WARNING If damage corrosion or deterioration is found return your Sage to an...

Страница 9: ...NING SAFE MINUTES VALUE IS OXYGEN TIME REMAINING TOTAL ASCENT TIME ELAPSED DIVE TIME or VALUE IS GAS PRESSURE IN PSI OR BAR or GAS MIX AIR OR NITROX 21 100 O2 BATTERY CONDITION IS GOOD SURFACE ONLY LO...

Страница 10: ...They are also used to enter settings and acknowledge the audible alarm Pressing different combinations of these buttons will navigate through different menus and options of the Sage The symbols in the...

Страница 11: ...access Alt screens to step down the screen advance through selections to toggle or change setpoints SELECT ADV MODE to exit a menu directly to the Main screen to access Compass Menu on the Surface in...

Страница 12: ...12 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 DIVE FEATURES...

Страница 13: ...hically as the N2 Bar Graph see Bar Graphs later in this section As you ascend the N2 Bar Graph will recede as control shifts to slower compartments This is a feature of the decompression model that i...

Страница 14: ...ive DIVE ALT 1 50 F 132 11 56 MAX FT 37 87FT AM SAFE MINUTES the value is Air Time Remaining BAR GRAPHS The Sage features two specific bar graphs 1 The one in the center represents ascent rate It is r...

Страница 15: ...calculated Stop Depth for 10 seconds during the countdown the No Decompression Main will replace the Deep Stop Main display and the Deep Stop feature will be disabled for the remainder of that dive T...

Страница 16: ...he audible alarm will emit 1 beep per second for 10 seconds when alarms strike During that time the audible alarm can be acknowledged and silenced by pressing the SELECT button The audible alarms will...

Страница 17: ...17 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 AIR NX SURFACE MODE...

Страница 18: ...after a dive gas pressure Gas Desaturation Time battery status gas mix surface time hr min Bluetooth blank if off residual nitrogen time of day date Time to Fly 2335 AIR GAS 1 PSI 1 39 SURF TIME 10 4...

Страница 19: ...has been no previous dive within the current activation cycle 10 39AM 11 25 16 0 43 DIVE TIME LAST DIVE 32 4M ALT 2 The ALT 2 screen displays current elevation and temperature 50 F SEA ELEVATION ALT...

Страница 20: ...in the order they appear in the menu below SELECT ADV MODE MAIN MENU PLAN LOG HISTORY SETUP MODE DC INFO MY INFO to scroll down to scroll up SELECT ADV MODE 2335 AIR GAS 1 PSI 1 39 SURF TIME 10 46AM 7...

Страница 21: ...will automatically be set to 21 The AIR option will not be displayed as an FO2 setting until 24 hours elapse after the last dive NOTE When FO2 is set for AIR oxygen related data such as PO2 O2 will n...

Страница 22: ...s is triggered the critical data will flash on the Dive Main screen SELECT ADV MODE ALARMS MENU AUDIBLE END RESERVE TIME N2BG ASCENT DEPTH TURN to scroll down to scroll up to select option SELECT ADV...

Страница 23: ...set OFF When set OFF the alarm will not sound as ascent rate increases SELECT ADV MODE SET DEPTH ALARM ON OFF ON SET to toggle selection to toggle selection to save setting C DEPTH Factory set ON the...

Страница 24: ...Pressure Alarm allows you to set an alarm for when you reach a designated end pressure You may choose from from 300 to 1500 PSI 20 to 105 BAR in increments of 100 PSI 5 BAR SELECT ADV MODE 1000 3000...

Страница 25: ...F When set OFF the Alarm will not sound as Safe Minutes de creases toward 0 minutes SELECT ADV MODE SET RESERVE TIME ALARM SET OFF ON SET to toggle selection to toggle selection to select or save opti...

Страница 26: ...back to Setup Menu to select an option 3 UTILITIES Within the Set Utilities menu you can customize the following five operational functions SELECT ADV MODE SET H2O SENSOR ON OFF ON to toggle selectio...

Страница 27: ...ives NOTE New data will automatically overwrite the oldest data in memory when the memory becomes full The Sage Log and PC Download data is stored separately in different partitions of the memory The...

Страница 28: ...ggle selection to toggle selection to save setting D DEEP STOP The Deep Stop feature see p 15 can be set ON or OFF SELECT ADV MODE SET CONSERVATIVE FACTOR ON OFF ON to toggle selection to toggle selec...

Страница 29: ...MAT HOUR FORMAT to scroll down to scroll up back to Setup Menu to select an option 4 DATE TIME Within this menu you can set the formats date and time of day SELECT ADV MODE 12 HR 24 HR SET HOUR FORMAT...

Страница 30: ...alue to decrease value to save hour min or AM PM B SET HOUR Set the hour minute and AM PM if set for 12 hour format SELECT ADV MODE SET DATE FORMAT D M Y M D Y D M Y to toggle selection to toggle sele...

Страница 31: ...ET YEAR 2016 2016 2065 to increase value to decrease value to save year D SET DATE Set the year month and day SELECT ADV MODE SET MONTH 2 FEBRUARY to increase value to decrease value to save month SEL...

Страница 32: ...tarted It will return to sniffing mode when the Sage enters Surface Mode SELECT ADV MODE SET BLUETOOTH ON OFF ON to toggle selection to toggle selection to save setting to increase value to decrease v...

Страница 33: ...iverlog interface The screen shown below will be displayed until information has been uploaded SELECT ADV MODE MY INFO JOHN DOE 90 111 222 3333 A RH CONTACT JANE DOE 90 111 222 4444 to exit DC DIVE CO...

Страница 34: ...Time limits are displayed depend ing on whether nitrogen or oxygen levels will be the limiting factor The time limit will display as 1 599 minutes all times greater than 599 display as 599 NOTE Depth...

Страница 35: ...eds 599 min the data at the 599 interval is recorded in the Log upon surfacing of the unit The log has a capacity of 50 total records NOTE New data will automatically overwrite the oldest data in memo...

Страница 36: ...Pelagic 2017 Doc No 12 7864 r06 8 21 17 HISTORY History is a summary of basic data recorded during all AIR NX and GAUGE dives SELECT ADV MODE 189 157 2 32 LEV3 FT TOTAL DIVES MAX DEPTH MAX DIVE TIME M...

Страница 37: ...37 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 AIR NX DIVE OPERATION...

Страница 38: ...nformation in this chapter demonstrates and describes an uneventful dive in terms of safety Alarms are described in the Complications section of this chapter WARNING Before diving with the Sage take t...

Страница 39: ...elow the calculated Deep Stop depth The stop time will be displayed and count down to 0 00 min sec as long as you stay within 10 ft 3 m above or below the stop See Deep Stop in the Dive Features chapt...

Страница 40: ...Once the surface time reaches 10 minutes the Sage will display the standard AIR NX Surface screen NOTE The Sage requires a 10 minute surface interval to record a subsequent dive as a separate dive in...

Страница 41: ...in which a violation occurred Overview All dives begin with GAS 1 The GAS defaults to 1 after 10 minutes on the surface Gas switches can only be made when a AIR NX Dive Main screen is displayed Gases...

Страница 42: ...n Depth with slightly less credit given the deeper you are below the Stop Depth indicated You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth app...

Страница 43: ...llower than a Deco Stop Depth for more than 5 minutes operation will enter DV1 which is a continuation of CV with penalty time still being added Again the audible alarm will sound and the full N2 Bar...

Страница 44: ...GM when Decompression requires a Stop Depth greater than 70 ft 21 m Operation would then continue in VGM during the remainder of that dive and for 24 hours after surfacing VGM turns the Sage into a di...

Страница 45: ...S 1 NX 32 flashing flashing Alarm When O2 reaches the Alarm Level the audible alarm sounds O2 Safe Minutes display 0 O2 SAT saturation value and up arrows if not in decompression will flash until the...

Страница 46: ...46 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 GAUGE OPERATION MODE...

Страница 47: ...AM 7 28 16 GAUGE SURFACE MAIN no dives yet gas pressure battery status surface time hr min Bluetooth blank if off time of day date 2967PSI SURF TIME 10 34 13 26 FLY GAUGE GAUGE SURFACE MAIN post dive...

Страница 48: ...ess the SELECT button to choose options from the Gauge Menu SELECT ADV MODE MAIN MENU MODE LOG SETUP HISTORY to scroll down to scroll up SELECT ADV MODE 2967PSI SURF TIME 1 06 GAUGE 10 46AM 7 28 16 to...

Страница 49: ...NX Mode SELECT ADV MODE to access Compass Mode to access Set Brightness screen ALT back to Main ADV 2967PSI SURF TIME 1 06 GAUGE 10 46AM 7 28 16 Set Brightness operates the same during a dive as on t...

Страница 50: ...epth on the Alt screen will also be represented by dashes The maximum functional depth Dive Gauge 330 ft 100 m is the depth at which the Sage can properly perform calculations or provide accurate disp...

Страница 51: ...51 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 COMPASS MODE...

Страница 52: ...7864 r06 8 21 17 1 DEPTH OR SURFACE TIME 2 REFERENCE OR REVERSE HEADING 3 ASCENT RATE 4 HEADING 5 HEADING MARKER 6 CARDINAL INTERCARDINAL POINTS 7 DIVER S DIRECTION LUBBER LINE COMPASS DISPLAY ICONS...

Страница 53: ...ading marker and diver s direction lubber line are green when on heading and amber when off heading NOTE Similar to an analog compass magnetic and ferrous metals can cause erratic and erroneous readin...

Страница 54: ...ET DECLIN CALIBRATE to scroll down to scroll up to step back to select an option exit menu CALIBRATE You may need to calibrate the compass from time to time to compensate for any magnetic interference...

Страница 55: ...declination value for any region can be found on current geographical charts By correcting for declination you can achieve a more accurate compass reading NOTE Magnetic north changes over time so use...

Страница 56: ...direction you should turn to correct your course The heading can be removed at anytime by holding the Advance button for at least 2 seconds SELECT ADV MODE remove heading 049 E N 75FT NE SET HEADING t...

Страница 57: ...57 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 REFERENCE...

Страница 58: ...AND SERVICE Your Sage should be inspected annually by an Authorized Sherwood Dealer who will perform a factory prescribed function check and inspection for damage or wear To keep the 2 year limited wa...

Страница 59: ...minute Temperature 0 to 99 F 18 to 60 C 1 Surface Interval 0 00 to 23 59 hr min 1 minute Time to Fly 23 50 to 0 00 hr min 1 minute starting 10 min after the dive Time to Desaturate 23 50 max to 0 00 h...

Страница 60: ...ed from factory in Deep Sleep mode Power Saver Mode surface Activates and turns screen off when 2 minutes elapse on surface with no button operations Resume operation from Power Saver Mode by pressing...

Страница 61: ...06 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 04 0 03 0 03 0 03 190 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 NO DECOMPRESSION LIMITS AT ALTITUDE METRIC Altitude 0 305 610...

Страница 62: ...osing the use of your Sage a backup instrument system is highly recommended INSPECTION SERVICE RECORD Sage Serial Number _______________________________________________________________________________...

Страница 63: ...63 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 NOTES...

Страница 64: ...64 SAGE MANUAL Pelagic 2017 Doc No 12 7864 r06 8 21 17 Sage DIVE COMPUTER MANUAL...

Отзывы: