13
16
Trunk/
Doors
Shock
Ignition
Hood Trigger
Trigger
Sensor Trigger
Trigger
OPERATION
CLEARING THE FLASHING ICON AND MELODY:
While
triggering the alarm the LCD screen will alert the user with
a melody and flashing trigger icon. Pressing the
F
button
3 times within 3 seconds
will clear the flashing icon and
stop the melody on the LCD screen transceiver.
STOP THE MELODY ONLY:
While triggering the alarm, the
LCD screen will alert the user through a melody and flashing trigger icon,
press any button on the LCD remote transceiver to stop the melody only.
Warn-away
Trigger
NOISE ABATEMENT CIRCUIT:
Your system has a
Noise Abatement
Circuit
. This feature prevents annoying repetitive trigger sequences due
to a faulty door pin switches or environmental conditions such as thunder,
jackhammers, airport noise, etc.
Heres how the
Noise Abatement Circuit
works: The alarm triggers five
times. Each time, the same sensor or switch is triggering the alarm, the
Noise Abatement Circuit
will interpret this pattern of triggers or false
alarms. After the fifth trigger, the
Noise Abatement Circuit
ignores, or
bypasses, that sensor until another sensor or switch is triggered.
The
Noise Abatement Circuit
covers the doors (doors, hood and trunk)
differently: If the alarm is triggered by an open door for six full cycles, the
doors will be bypassed until the trigger ceases.
O. ANTI CAR- JACKING
Warning: If you don't need the car jacking function in this
alarm system, be sure to set car jacking feature to the OFF
setting. This system default setting for car-jacking is OFF.
OPERATION
V. CHANNEL 4 TIMER CONTROL OUTPUT
Press the transmitters and
buttons
at the same time
to activate the
Channel 4 function
. Channel 4 is a user-
programmable timer output. You may program the built-in
timer to send a ground signal for any time duration from 1
second to 120 seconds. For instance, this timer output may
be used to turn on the headlights, power windows or sunroof.
(The factory default setting is a momentary output.)
W. POWER ON MEMORY:
This security system is equipped with circuitry that will allow the unit to
remember its alarm state
if the vehicles battery power is disconnected.
S. DOME LIGHT CONVENIENCE DELAY AND SUPERVISION
The alarm has a unique feature which will turn on your vehicles
Dome Light as follows
:
1.
Upon disarming, the dome Light will remain on for 30 seconds.
2.
If the vehicle is intruded, the dome Light will flash for the same duration
as the siren.
Note: Turning ON the ignition switch or arming the alarm will turn
off the dome light.
T. IGNITION CONTROLLED DOOR LOCKING AND UNLOCKING
(See Alarm Feature II-3 Programming.)
1.
Turn the ignition switch ON and close all the vehicles doors. After 3
seconds, the system will automatically lock the central locking system.
2.
Turn the ignition switch OFF. The system will automatically unlock the
central locking system.
U. TRUNK RELEASE (CHANNEL 3) OUTPUT.
CHANNEL 3 TIMER CONTROL OUTPUT
(See Alarm Feature III-3 Programming.)
Press and hold
the
button
on the transmitter for
(2)
sec.
to open the trunk release or any other electric devices that has
been added to this output.
Channel 3 is user-programmable timer output. You may program the built=in
timer to send a ground signal for any time interval between 1 second and
2 minutes. For instance. this timer output may be used to turn on the
headlights, power windows or sunroof.
NOTE:
Factory default setting at 1
second pulse grounded for trunk release output.
Содержание CS-500S