72
Maintenance &
Tr
oubleshooting
Replacing the Lamp
• Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage
or the inside of the projector.
• To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.
• Replace the lamp more safely by unplugging the power cord after turning off the main power.
Removing and installing the lamp unit
CAUTION
4
6
Remove the lamp
cage.
5
Attach the lamp cage cover
and turn on the main power.
1
3
Turn off the power.
2
Turn off the main
power.
Turn off the MAIN POWER
switch. (Unplug the power cord.)
Remove the lamp cage
cover.
Press POWER ON on projector. LAMP
REPLACEMENT indicator flashes red.
Then press ENTER to reset lamp timer.
Press
POWER ON
, and then
press
ENTER
on the projector.
Remove the securing screws
from the lamp cage. Hold the
lamp cage by the handle and
pull it horizontally towards you.
Loosen the user service screw
that secures the lamp cage
cover on the back of the
projector. Then slide the cover in
the direction of the arrow (to the
open mark).
Press
POWER OFF
. Wait until
the cooling fan stops.
Slide the lamp cage cover in the
direction of the arrow (to the
close mark) on the back of the
projector. Then turn on the MAIN
POWER switch.
7
Turn off the main power again and
remove the lamp cage cover.
Insert the new lamp
cage.
Press the lamp cage firmly into
the lamp cage compartment.
Fasten the securing screws.
Turn off the main power switch
and slide the lamp cage cover
in the direction of the arrow (to
the open mark) on the back of
the projector.
Slide the lamp cage cover in the
direction of the arrow (to the
close mark) on the back of the
projector. Then tighten the user
service screw.
8
or
Securing screws
Securing screw
Lamp 1
High angle view
Lamp 2
Attach the lamp cage
cover.
9
• You need to reset lamp timer every time when replacing the lamp and confirm it to be reset on “Lamp Timer” menu.