17
E
E
E
E
E
STEP-BY-STEP INSTALLATION GUIDE
C. RECIRCULATING (NON-VENTED DUCTLESS)
Installation overview
C1. Attach the mounting plate to the wall
C2. Use Top Cabinet Template for preparation of top cabinet
C3. Adapt blower for recirculation
C4. Mount the microwave oven
C5. Change the charcoal filter
C1.
ATTACH MOUNTING PLATE TO THE WALL
Attach the mounting plate to the wall using the wing nuts and toggle
bolts (
3
⁄
16
" x 3" / 0.5 x 7.6 cm). At least one lag screw must be used
to attach the mounting plate to a wall stud.
1.
Insert the toggle bolts (
3
⁄
16
" x 3" / 0.5 x 7.6 cm) into the mounting
plate through the holes designed to go into drywall and attach
the wing nuts to
3
⁄
4
" (1.9 cm) onto each toggle bolt (
3
⁄
16
" x 3" /
0.5 x 7.6 cm).
2.
Place the mounting plate against the wall and insert the wing nuts
into the holes in the wall to mount the plate.
CAUTION
Be careful to avoid pinching fingers between the
back of the mounting plate and the wall.
3.
Tighten all bolts. Pull the mounting plate away from the wall to
help tighten the bolts.
5
/
8
"
Wall
Toggle
Bolt
Wing nut
Bolt end
Spacing for toggles more
than wall thickness
C2.
USE TOP CABINET TEMPLATE FOR PREPARATION
OF TOP CABINET
You need to drill holes for the top support screws, a hole large enough
for the power cord to fit through.
• Read the instructions on the Top Cabinet Template.
• Tape the template underneath the top cabinet bottom.
• Drill the holes, following the instructions on the Top Cabinet
Template.
CAUTION
Wear safety goggles when drilling holes in the
cabinet bottom.