R-211A
9
1000g
1000g
1000g
T1˚C
T2˚C
Heat up for 62 sec.
B
POWER TRANSFORMER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads to the primary winding of the power transformer. Disconnect the filament and
secondary winding connections from the rest of the HV circuitry. Using an ohmmeter, set on a low
range, it is possible to check the continuity of all three windings. The following readings should be
obtained:
WARNING: High voltages and large currents are present at the secondary winding and
filament winding of the power transformer. It is very dangerous to work near this
part when the oven is on. NEVER make any voltage measurements of the high-
voltage circuits, including the magnetron filament.
If the reading obtained are not stated as above, then the power transformer is probably faulty and
should be replaced.
CARRY OUT 4R CHECKS.
Initial temperature .................................................................................................. T1 = 11
°
C
Temperature after (60 + 2) = 62 sec. ..................................................................... T2 = 21
°
C
Temperature difference Cold-Warm ....................................................................
∆
T1 = 10
°
C
Measured output power
The equation is “P = 70 x
∆
T” ....................................................... P = 70 x 10
°
C = 700 Watts
JUDGMENT: The measured output power should be at least
±
15 % of the rated output power.
CAUTION: 1
°
C CORRESPONDS TO 70 WATTS. REPEAT MEASUREMENT IF THE POWER IS
INSUFFICIENT.
a.Primary winding ................ 1.9 ohms approximately
b.Secondary winding ........... 162 ohms approximately
c.Filament winding .............. less than 1 ohm
C
HIGH VOLTAGE RECTIFIER ASSEMBLY TEST
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
HIGH VOLTAGE RECTIFIER TEST
CARRY OUT 3D CHECKS.
Isolate the high voltage rectifier assembly from the HV circuit. The high voltage rectifier can be tested
using an ohmmeter set to its highest range. Connect the ohmmeter across the terminal B+C of the
high voltage rectifier and note the reading obtained. Reverse the meter leads and note this second
reading. The normal resistance is infinite in one direction and more than 100 k
Ω
in the other direction.
CARRY OUT 4R CHECKS.
NOTE: FOR MEASUREMENT OF THE RESISTANCE OF THE RECTIFIER, THE BATTERIES OF
THE MEASURING INSTRUMENT MUST HAVE A VOLTAGE AT LEAST 6 VOLTS, BE-
CAUSE OTHERWISE AN INFINITE RESISTANCE MIGHT BE SHOWN IN BOTH DIREC-
TIONS.
B
C
HIGH VOLTAGE RECTIFIER
Содержание R-211A
Страница 2: ...R 211A ...
Страница 28: ...R 211A 26 97SHARP CORP 6K0 070E Printed in Japan ...