R-211A
17
2. Re-connect wire leads to each switch. Refer to chapter
"Pictorial Diagram".
3. Secure latch hook (with two (2) mounting screws) to
oven flange.
4. Re-install the switch lever and the control panel as-
sembly to the oven cavity front flange.
5. Re-connect wire leads to the timer motor. Refer to
chapter "Pictorial Diagram".
6. Make sure that monitor switch is operating properly
and check continuity of the monitor circuit. Refer to
chapter "Test Procedure", and Adjustment Procedure
below.
1ST. LATCH SWITCH, 2ND. LATCH SWITCH AND MONITOR SWITCH ADJUSTMENT
If the 1st. latch switch, 2nd. latch switch and monitor switch
do not operate properly due to a misadjustment, the
following adjustment should be made.
1. Loosen the two (2) screws holding the latch hook to the
flange of the oven front face.
2. With the door closed, adjust latch hook by moving it
back and forth and up and down. In and out play of the
door allowed by the upper and lower position of the
latch hook should be less than 0.5mm. The horizontal
position of the latch hook should be adjusted so that the
monitor switch is activated with the door closed. The
vertical position of the latch hook should be adjusted so
that the 1st. latch switch and the 2nd. latch switch are
activated with the door closed.
3. Secure the screws firmly.
4. Check the operation of all switches. If each switch has
not activated with the door closed, loosen screw and
adjust the latch hook position.
After adjustment, make sure of the following.
1. In and out play of the door remains less than 0.5mm
when in the latched position. First check upper position
of latch hook, pushing and pulling upper portion of door
toward the oven face. Then check lower portion of the
latch hook, pushing and pulling lower portion of door
toward the oven face. Both results (play in the door)
should be less than 0.5mm.
2. The 1st. latch switch and 2nd. latch switch interrupt the
circuit before the door can be opened.
3. The monitor switch contacts close when the door is
opened.
4. Re-install outer case and check for microwave leakage
around the door with an approved microwave survey
meter. (Refer to Microwave Measurement Procedure.)
LATCH HOOK
LATCH
HEADS
DOOR
MONITOR SWITCH
1 ST. LATCH
SWITCH
SWITCH LEVER
2ND. LATCH
SWITCH
Figure C-7. Latch Switch Adjustments
DOOR REPLACEMENT
7. Release two (2) pins of door panel from two (2) hole of
upper and lower oven hinges by lifting up.
8. Now, door panel is free from oven cavity.
9. Release door panel from ten (10) tabs of door frame
and remove door frame by sliding the door panel
downward.
10.Now, door panel with sealer film is free.
11.Tear sealer film from door panel.
12.Now, door panel is free.
13.Slide latch head upward and remove it from door frame
with releasing latch spring from door frame and latch
head.
14.Now, latch head and latch spring are free.
15.Remove door screen from door frame.
16.Now, door screen is free.
RE-INSTALL
1. Re-install door screen to door frame.
2. Re-install latch spring to the head. Re-install latch
spring to the door frame. Re-install latch head to the
door frame.
3. Re-install door panel to door frame by fitting ten (10)
tabs of door frame to ten (10) holes of door panel.
4. Put sealer film on door panel. Refer to "Sealer Film"
REMOVAL
1. Disconnect oven from power supply.
2. Push the open button and open the door slightly.
3. Insert a putty knife (thickness of about 0.5mm) into the
gap between the choke cover and corner portion of
door panel as shown in Figure C-8 to free engaging
parts.
4. Try the principles of the lever and lift up the choke cover
by inserting a putty knife in order shown in figure C-8.
5. Release choke cover from door panel.
6. Now choke cover is free.
Putty Knife
Choke Cover
1
2
3
4
5
6
7
8
9
10
11
12
Door Panel
Figure C-8. Door Disassembly