MX-M200D SIMULATIONS 7-34
46
19
Exposure mode setting (
table setting/AE operation mode setting/Photo image process setting)
Used to set the following three items. Select an item with the [ ] key or [ ] key and enter a set value with
numeric keys.
(1) :
table setting
(2) : AE operation mode
(3) : PHOTO image process setting
When this simulation is executed, the current set code number of the above three modes are displayed.
(1) AE MODE(
table setting)
Used to set the priority operation mode of the AE mode. When the image takes priority regardless of the
toner consumption, set to 1. When the toner consumption must be suppressed regardless of image quality,
set to 2.
* If this setting is changed, SIM 46-30 returns to the default.
Default:
2
(2) AE STOP (AE operation mode)
Used to set the area for automatic exposure correction in image process.
Default:
0
(3) PHOTO (PHOTO image process setting)
Used to set the image process when the PHOTO mode is selected. Selection is available in the following
two modes:
Default:
2
20
SPF/RSPF exposure correction
Used to set the exposure correction amount in the SPF/RSPF mode. (Since a slightly darker image is
outputted in the SPF/RSPF mode compares to the OC mode, the difference from the OC mode is corrected
with this simulation. When, therefore, the exposure in the OC mode is corrected, the SPF/RSPF exposure is
also changed accordingly.)
Enter a correction value with numeric keys and press [OK] key. The adjustment value is saved in the
EEPROM and the machine shifts to the adjustment copy window. Since this simulation is used to make up
for the exposure difference from the OC mode regardless of the exposure mode, the adjustment is fixed to
TEXT mode and the exposure mode cannot be changed. After completion of copying for check, the machine
returns to the setting window.
The adjustment value is in the range of 1 - 99.
Adjustment value (Image change) 99 (Dark) • • • 50 (Default) • • • 1 (Light)
(Only when the
SPF/RSPF is
installed.)
Default:
50
Main
code
Sub
code
Contents
Remark
Sim46-19 AE MODE
1:AE MODE
2:AE STOP
3:PHOTO
[ 1- 2]
1
0
1
1
Code number
table setting
1
Priority on image quality
2
Priority on toner consumption
Code number
AE operation mode
0
Lead edge stop
1
Real time process (All areas)
Code number
Image process mode
1
Error diffusion process
2
Dither process
Sim46-20 SPF EXP.
1:SPF EXPOSURE
[ 1- 99]
50
50