Sharp MX-FXX1 Скачать руководство пользователя страница 59

MX-FXX1  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 50

SW 
No.

Bit 

No.

Item

SW selection and function

Initial value

System 

settings

122

1-8

Not used

1

Refer to "SW122, 1-8 
Initial value"

0
1
1
0
1
0
0

123

1-8

Not used

0

Refer to "SW123, 1-8 
Initial value"

124

1-8

Not used

1

Refer to "SW124, 1-8 
Initial value"

0
0
0
0
1
1
1

125

1-8

Not used

0

126

1-8

Not used

0

Refer to "SW126, 1-8 
Initial value"

127

1-8

Not used

0

Refer to "SW127, 1-8 
Initial value"

0
0
0
0
1
1
0

128

1-8

Not used

0

Refer to "SW128, 1-8 
Initial value"

SW122, 1-8 Initial value

"10110100": North America/U.K./France/Germany/Sweden/Finland/Norway/Denmark/Netherlands/Italy/Switcherland/Austria/Indonesia/Philippine/Middle 
East/Slovakia/Other3/Rusia/Spain/Portuguese/Luxemburg/Belgium/Czech/Hungary/Greece/Poland
"01001011": Malaysia/Taiwan/South Africa
"01101001": New Zealand/India
"10000111": Australia
"10010110": China/Singapore/Thailand/Hong Kong

SW123, 1-8 Initial value

"00000000": Other country
"00010000": France

SW124, 1-8 Initial value

"10000111": North America/Australia/U.K./France/Germany/Sweden/Finland/Norway/Denmark/Netherlands/Italy/Switcherland/Austria/New Zealand/
Singapore/Indonesia/Malaysia/India/Philippine/Taiwan/Middle East/Slovakia/Other3/Rusia/South Africa/Spain/Portuguese/Luxemburg/Belgium/Czech/
Hungary/Greece/Poland
"10100101": China/Thailand/Hong Kong

SW126, 1-8 Initial value

"00000000": North America/New Zealand/China/Indonesia/Thailand/Malaysia/Philippine/Hong Kong/Taiwan/Middle East/Other3
"00000010": India
"00000011": Australia/Singapore/South Africa
"00000100": U.K./France/Germany/Sweden/Finland/Norway/Denmark/Netherlands/Italy/Switcherland/Austria/Slovakia/Rusia/Spain/Portuguese/Luxemburg/
Belgium/Czech/Hungary/Greece/Poland

SW127, 1-8 Initial value

"00000110": North America/Australia/Taiwan/Middle East/Other3
"00000100": China/Indonesia/Thailand/Malaysia/Philippine/Hong Kong
"00001010": New Zealand
"00100100": Singapore/India/South Africa
"01000100": U.K./France/Germany/Sweden/Finland/Norway/Denmark/Netherlands/Italy/Switcherland/Austria/Slovakia/Spain/Portuguese/Luxemburg/
Belgium/Czech/Hungary/Greece/Poland
"01000110": Rusia

SW128, 1-8 Initial value

"00000000": Other country
"00100000": Australia

Содержание MX-FXX1

Страница 1: ...only The contents are subject to change without notice 1 PRODUCT OUTLINE 1 1 2 SPECIFICATIONS 2 1 3 UNPACKING AND INSTALLATION For how to unpacking and installation refer to the installation manual 00ZMX2700 I1E 4 EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 1 5 SIMULATIONS FAX SOFTWARE SWITCH 5 1 6 TROUBLE CODE 6 1 7 MACHINE OPERATION 7 1 8 ELECTRICAL SECTION 8 1 CONTENTS CODE 00ZMXFXX1 S1E MX FXX1 M...

Страница 2: ... Touch panel of FAX mode 4 1 5 SIMULATIONS FAX SOFTWARE SWITCH 1 Simulation 5 1 2 FAX software switch 5 19 6 TROUBLE CODE 1 Trouble code list 6 1 2 Details of trouble code 6 1 3 Communication report codes 6 2 4 Dial tone 6 5 7 MACHINE OPERATION 1 System settings list 7 1 2 Transmittable original sizes 7 3 3 Automatic reduction of the transmitted image 7 3 4 Adding your sender information to faxes ...

Страница 3: ...LINE 1 1 MXFXX1 Service Manual 1 PRODUCT OUTLINE This unit provides the FAX function and the PC FAX function when installed to the following machines 1 Configuration FAX BOX unit MX FXX1 FAX memory Facsimile expansion kit ...

Страница 4: ...aling 999 items including the one touch dialing items Program dialing Max 48 items Chain dialing Max 64 digits including one touch dialing 10 key dialing and pause Dial search Alphabet order search User index groups Quick search Yes LDAP search Yes Sub address Yes Password Yes Memory box registration Yes Standard 8M or 16M standard memory Memory extended 8MB memory included in the package Transmit...

Страница 5: ... mode No Sender registration function Yes Number of registration 1 for standard sender Max 200 for other users Default destination setting No Unauthorized scan prevention function Yes Filing each page function No Re operation function Yes User account function Yes Max 200 items additionally to the default Counter function Yes FAX FAX to e mail FTP Copier memory Local memory Printer memory System M...

Страница 6: ...Reception from a specific number not allowed To be rejected Specified numbers only 50 numbers 20 digits External phone connection remote Yes Confidential reception Sharp mode No Received data bypass output Yes Index printing No Transfer function upon disabling of output Yes 1 receiver of transfer registration Internet Fax Fax to e mail Transfer of Internet Fax Fax reception data to e mail inbound ...

Страница 7: ...eiver number sub address passcode including Program Registration of addresses groups settings density image quality and special functions in one set is allowed 48 of them Number of memory boxes Registration of bulletin board confidential relay broadcast is allowed up to 100 Registration name 18 characters Number of sender registration 1 default with 20 characters Number of sender selection registr...

Страница 8: ... One digit is cleared each time you press the key 5 key This is used to produce tone signals when you are on a pulse dial line 6 CA key clear all key Use to cancel a transmission or programming operation When this key is pressed the operation is cancelled and you return to the initial screen described on the following page This key is also used to cancel a resolution paper size or special function...

Страница 9: ...peed dial number 8 Speaker key Touch this key to dial using the speaker When entering a fax number to be dialed the key changes to the Pause key When entering a sub address the key changes to the Space key 13 key This key appears when one or more special modes have been selected Touch the key to display the selected special modes Address Review Sub Address Global Address Search Condition Settings ...

Страница 10: ... the FAX counter Data clear 46 39 Used to execute the image send sharpness adjustment FAX Adjustment 40 Used to execute the FAX exposure adjustment Collective adjustment of all the modes MFP FAX Adjustment 41 Used to execute the FAX exposure adjustment Normal MFP FAX Adjustment 42 Used to execute the FAX exposure adjustment Fine text MFP FAX Adjustment 43 Used to execute the FAX exposure adjustmen...

Страница 11: ... to NO When however the handset is not installed the sound volume cannot be checked Japan model only Setting FAX 24 Used to clear the FAST save data Data clear FAX 25 Used to register the FAX number for MODEM dial in Setting FAX 26 Used to register external telephone numbers for MODEM dial in Setting FAX 29 Used to initialize the telephone book data the one touch registration table the FTP Desktop...

Страница 12: ...ey is pressed the data are saved to EEPROM and RAM When C CA SYSTEM SETTINGS or EXECUTE button is pressed during printing the operation is interrupted Set range and default value of each setup FAX OUTPUT Print quantity counter for line 1 FAX OUTPUT_L2 Print quantity counter for line 2 FAX SEND Send counter FAX RECEIVED FAX receive counter SEND IMAGES FAX send quantity counter for line 1 SEND IMAGE...

Страница 13: ...ed and the value is dis played in the setting area If there is any item over an active display is made and item is shifted If there is no item over the display grays out and the operation is invalid If there is any item under an active display is made and item is shifted If there is no item over the display grays out and the operation is invalid 2 Enter the set value with 10 key When C key is pres...

Страница 14: ...Half tone 1 to 99 50 L EXPOSURE5 H_TONE Fine Exposure 5 Half tone 1 to 99 50 M EXECUTE MODE AUTO Print mode Fine Auto 1 to 12 1 1 AUTO EXP1 Fine Exposure 1 2 EXP2 Fine Exposure 2 3 EXP3 Fine Exposure 3 4 EXP4 Fine Exposure 4 5 EXP5 Fine Exposure 5 6 AUTO H_TONE Fine Auto Half tone 7 EXP1 H_TONE Fine Exposure 1 Half tone 8 EXP2 H_TONE Fine Exposure 2 Half tone 9 EXP3 H_TONE Fine Exposure 3 Half ton...

Страница 15: ...Purpose Adjustment Function Purpose Used to execute the FAX exposure level adjustment and the individual setting 600DPI Section FAX Item Image quality Operation Procedure 1 Select the set item with and buttons The highlighted set value is switched and the value is dis played in the setting area If there is any item over an active display is made and item is shifted If there is no item over the dis...

Страница 16: ...er the set value with 10 key Press C key to clear the entered values 4 When OK button is pressed the current entered value is saved to EEPROM and RAM When button COLOR or BLACK key is pressed the data are saved to EEPROM and RAM When CLOSE button is pressed the display is shifted to the copy basic screen of simulation Copying can be performed also by pressing COLOR BLACK key Item Display item Deta...

Страница 17: ...y is pressed the display returns to the initial set ting screen 4 When EXECUTE button is pressed it is highlighted and YES and NO buttons become active The country name is displayed on the tile line When NO button is pressed EXECUTE button returns to the normal display and YES and NO buttons become inactive Item Display item Description Set range Default value FAX send A Image loss setting OC LEAD...

Страница 18: ...EXECUTE button is pressed after interrupting the operation memory check is resumed 4 After completion of memory check EXECUTE button returns to the normal display and the result of memory check is dis played For the memory which is not installed NO CHECK is dis played In the case of REPEAT check the following display is made for every execution CHECKING 0001 CHECKING 0002 CHECKING 0003 The number ...

Страница 19: ...selected 3 When EXECUTE button is pressed it is highlighted and sig nals are sent 4 To end signal send When EXECUTE button is pressed it is highlighted and signal send is interrupted 66 6 Purpose Data output Check Function Purpose Used to print the confidential registration check table BOX NO BOX name pass code If there is no confidential registra tion no print is made Section FAX Item Data Confid...

Страница 20: ...sound message table of SIM66 08 Section FAX Item Operation Operation Procedure 1 When the machine enters Simulation 66 09 the following screen is displayed Default left upper setting 2 When a button of a sound message to be sent is selected it is highlighted and the previously set button returns to the normal display Only one sound message to be sent can be selected 3 When EXECUTE button is presse...

Страница 21: ...66 13 the following screen is displayed The number saved in the memory is displayed in the column of PRESENT If there is no data is displayed 2 Enter a number with 10 key The entered number is displayed in the column of NEW After entering 20 digits 10 key is disabled no response Only C key is enabled 10 key 0 to 9 C key back by one digit 3 When SET key is pressed after completion of entry the ente...

Страница 22: ... button is pressed it is highlighted and the dial pulse signal is sent from the line by the setting of high low group of the signal send level 3 To terminate the dial test press EXECUTE button The button returns to the normal display and the test is terminated When dialing the dial number is completed EXECUTE button returns to the normal display and the test is terminated 66 17 Purpose Operation t...

Страница 23: ...formation communication management information file management information system error protocol moni tor Section FAX Item Data Operation Procedure 1 When an item button to be printed is selected it is highlighted and the previously set button returns to the normal display Default select Left upper Only one item can be selected 2 Press EXECUTE button EXECUTE button is highlighted and printing is s...

Страница 24: ...ion FAX Item Data clear Operation Procedure 1 When the machine enters Simulation 66 25 the following screen is displayed The stored number is displayed in the column of PRESENT If there is no data is displayed 2 Enter a number with 10 key Entry can be made up to 20 digits After entering 20 digits 10 key is disabled Only C key is enabled The entered number is displayed in the column of NEW 10 key 0...

Страница 25: ...Simulation 66 31 the following screen is displayed When starting execution of the simulation the current set ting is displayed 2 Change the port setting When a port is set to ON the port display is highlighted Two or more ports can be selected At that time the actual port output is not reflected 3 When EXECUTE button is pressed the changed setting is reflected to the port which outputs to TEL LIU ...

Страница 26: ...ion check is started After completion of the operation check EXECUTE button returns to the normal display and the check result is displayed When the check is normally completed OK is displayed In case of an error NG is displayed 3 2 When Operation check repeat is selected When repeat is selected When EXECUTE button is pressed under this state EXECUTE button is highlighted and the operation check i...

Страница 27: ... When the machine enters Simulation 66 43 the following screen is displayed Default left upper selected Use buttons to select the select item of the power control adjustment value Selection is made in Item A to H When the selected item is the top last item buttons gray out The highlighted section of the set value is switched and the new value is displayed on the setting area When buttons gray out ...

Страница 28: ...ity selection when transmitting filed document files by FAX 1 Apply 0 Do not apply 0 Do not apply Operation settings 7 8 Not used 0 0 3 1 Received data printing hold FAX Internet FAX Setting to determine whether or not to store data received by FAX Internet FAX in the memory without outputting it 0 Do not hold 1 Hold 0 Do not hold Operation settings 2 3 Tone Pulse initial setting Dial call signal ...

Страница 29: ...ing 0 3 4 Volume of the reception completion sound Volume of the reception completion sound This sets the volume of the completion sound outputted from the speaker upon completion of FAX reception Volume is available in four types as follows 00 No sound 01 Small 10 Medium 11 Large 1 Medium FAX initial setting 0 5 6 Tone of the successful transmission sound This sets the tone sounded when transmiss...

Страница 30: ...verted to if a value outside of the setting range is set This functions when the communication results sheet print setting ordinary transmission broadcast transmission is set to be outputted 1 At times of error FAX initial setting 0 3 Automatic printing of the record sheet when memory is full Setting to determine whether or not to automatically output the communication record sheet when transmitte...

Страница 31: ...ountries this setting is fixed to OFF 00 OFF 01 Flash 10 ID The setting other than the above would be granted as the default 0 No invalid FAX initial setting 0 5 8 ID number setting Input the 1st digit when dial inputting and dialing Conduct ID No setting when the PBX function is valid Valid when ID is set using SW12 3 12 4 The initial value of 0 is reverted to if a value outside of the setting ra...

Страница 32: ... and transmit as B4 width B5 0 Rotate 1 Do not rotate 0 Rotate FAX transmission setting 4 Rotated transmission selection A5R A5 Rotated transmission or not depending on orientation of the document When transmitting A5R document this setting determines whether to transmit as A4 width A5R or to rotate the read image and transmit as A4 width A5 0 Rotate 1 Do not rotate 0 Rotate FAX transmission setti...

Страница 33: ...times by binary inputting If 0 is set the initial value of 2 times is adopted Number of recalls Setting x once The initial value is reverted to if a value outside of the setting range is set 0 2 times FAX transmission setting 0 1 0 19 1 4 Interval between re calls when busy Set the interval until the next re call when the line is busy during transmission This can be set from 0 to 15 minutes in 1 m...

Страница 34: ...heet is set 0 Reduce 1 Do not reduce discard When not reducing the area that cannot be printed is scrapped When set to Reduce the overall data are reduced to 94 1 Do not reduce discard FAX reception setting 21 1 4 Setting of the number of automatic reception calls Set the number of call sounds until the start of receiving holding of the line when automatic reception is set This can be set from 0 t...

Страница 35: ... changing over to automatic reception when in the manual reception mode This functions when the Setting for changing over to automatic reception during manual reception SW23 1 is valid Setting can be made over the range of 1 to 32 times by binary inputting 0 9 times FAX reception setting 1 0 0 0 7 Polling protection Set to determine whether or not to execute protection when the other party request...

Страница 36: ...vel 9 01 Volume level 11 10 Volume level 13 11 Volume level 15 1 Volume level 15 1 7 8 Volume setting of line monitor sound medium This sets the medium system setting volume level of the line monitor sound outputted from the speaker 00 Volume level 5 01 Volume level 7 10 Volume level 9 11 Volume level11 1 Volume level 11 1 26 1 2 Volume setting of line monitor sound small This sets the small syste...

Страница 37: ...onds x N 30 seconds T1 timer is the timer used from the point where the other party s machine recognizes CED or DCS as FAX following line connection 35 5 seconds according to the ITU T standard 0 40 seconds 0 1 0 5 8 Not used 0 0 0 0 33 1 2 T4 timer setting Timer during automatic operation 1 5 seconds at times of manual operation This sets the timer for up until reception of the response 1 5 secon...

Страница 38: ... to the other party s machine in V 34 communication 00 JBIG MMR MR MH 01 MMR MR MH 10 MR MH 11 MH 0 JBIG MMR MR MH 0 3 4 Line1 Coding capacity during transmission and reception other than V 34 communication reflected in DIS DCS DTC This sets the coding capacity that is communicated to the other party s machine in communication other than V 34 00 JBIG MMR MR MH 01 MMR MR MH 10 MR MH 11 MH 0 JBIG MM...

Страница 39: ...EEPROM access 0 EEPROM access permitted 1 EEPROM access prohibited 0 Access permitted 5 Not used 0 6 SDT signal detection Setting to determine whether or not to detect the SDT signal which is the second dial tone when transmitting to the F net When the SDT signal is not detected ordinary dialling is conducted even after 16X dialling 0 Do not detect 1 Detect 0 Do not detect 7 8 Timer setting V 21 F...

Страница 40: ...nds 1 2 0 seconds North America Taiwan Middle East Other3 Rusia 1 0 0 5 seconds Australia U K France Germany Sweden Finland Norway Denmark Netherlands Italy Switcherland Austria New Zealand China Singapore Indonesia Thailand Malaysia India Philippine Hong Kong Slovakia South Africa Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 0 3 Time between DCS TCF Setting to determine how many...

Страница 41: ...te excluding preheat 0 Do not revert 1 Revert 1 Revert 8 Not used 0 44 1 Echo suppressor tone setting No 1 Setting to determine whether or not to have the echo suppressor tone in the high speed modulation mode 0 With V33 1 Without V33 0 With V 33 2 Echo suppressor tone setting No 2 Setting to determine whether or not to have the echo suppressor tone in the high speed modulation mode 0 With V17 1 W...

Страница 42: ...o enable 3429Hz as the symbol rate for V 34 When this is at disable 3429Hz is not selected However only valid during transmission 1 enable 0 disable 1 enable 2 Symbol rate 3200 high carrier transmission enable during V 34 transmission When 3200Hz is selected as the V 34 symbol rate there are Low High carriers but this setting determines whether or not both can be used When this is at disable 3200 ...

Страница 43: ...nly functions when dial tone detection is OFF 0 3 5 seconds North America Australia France Germany Sweden Switcherland Austria China Singapore Indonesia Thailand Malaysia India Philippine Hong Kong Taiwan Middle East Other3 Rusia 0 0 4 seconds U K Finland Norway Denmark Netherlands Italy New Zealand Slovakia South Africa Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 1 50 1 7 Not u...

Страница 44: ...ia Rusia South Africa Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 0 0 0 53 1 2 Not used 0 0 3 Line current detection at times of dial calling Setting to determine whether or not to call dial following detection of line current during line connection at times of automatic dial calling 1 No 0 Yes In cases where the setting is Yes but no line current can be detected dial is not cal...

Страница 45: ... and busy tone Change the setting if dial tone and busy tone are erroneously detected 00 modem fixed 01 420Hz 680Hz 10 360Hz 440Hz 11 245Hz 650Hz For CTR21 245Hz 650Hz 1 11 245Hz 650Hz North America Australia U K France Germany Sweden Finland Norway Denmark Netherlands Italy Switcherland Austria New Zealand Singapore Philippine Hong Kong Taiwan Slovakia South Africa Spain Portuguese Luxemburg Belg...

Страница 46: ... 33ms Malaysia Taiwan South Africa 0110 35ms New Zealand India 1000 37ms Australia 1001 38ms China Singapore Thailand Hong Kong Adjustment value 0 1 1 5 8 Break time setting 10PPS Setting of break time when dialling at 10PPS Break time can be set from 56 to 71ms by in 1ms increments binary inputting N over the range of 0 to 15 N 56ms 0 0100 60ms North America U K France Germany Sweden Finland Norw...

Страница 47: ...n units of 1dB Setting can be made over the range of 0dB to 15dB in 1dB increments by binary inputting 0 0101 5dB North America Slovakia 0011 3dB Other3 Rusia 0110 6dB New Zealand China Singapore Thailand Philippine 0111 7dB U K France Germany Sweden Finland Norway Denmark Netherlands Italy Switcherland Austria Malaysia Taiwan Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 1000 8dB...

Страница 48: ...etection time This sets the lower limit time of the ON section when detecting frequency of the busy tone signal If busy tone signals are not detected in excess of this time do not count as 1 pulse 00 250ms 01 140ms 10 450ms 11 350ms 0 250ms North America Australia New Zealand China Singapore Indonesia Thailand Malaysia India Philippine Hong Kong Taiwan Middle East Other3 South Africa 0 0 140ms U K...

Страница 49: ...me to be continuous following ON detection of the call signal CI This is intended to treat the PBX call signal ring ring as a single call signal Setting can be made over the range of 0ms to 1500ms in 100ms increments by binary inputting 0 0110 600ms North America Australia Taiwan Middle East Other3 Rusia 0100 400ms U K France Germany Sweden Finland Norway Denmark Netherlands Italy Switcherland Aus...

Страница 50: ...This setting provides the countermeasure against that problem 0 Execute 1 Not execute 0 Execute 6 Manual calibration setting when a signal arrives Setting to execute the manual calibration or not when a signal arrives In case of an abnormal current waveform the auto calibration fails and the transmission is affected This setting provides the countermeasure against that problem 0 Execute 1 Not exec...

Страница 51: ...itted document contents at times of F code communication FAX only Setting to determine whether or not to print part of the transmitted document on the communication results sheet at times of F code communication However only when the Document contents printing at times of transmission setting is valid 0 Do not print 1 Print The Document contents printing results sheet at times of transmission sett...

Страница 52: ...utput en masse following completion of reception 1 Output 1 page at a time 0 Save and output en masse following completion of reception 6 7 Not used 0 0 8 Rotated printing Setting to determine whether or not to rotate and output received data when this is possible at times of receiving and printing FAX and Internet FAX data 0 Permitted rotate and print 1 Prohibited do not rotate and print 0 Permit...

Страница 53: ...ceipt of designated number is not refused invalid 1 Receipt of designated number is refused valid However at times of automatic reception perform using a separate SW Setting to refuse reception at times of automatic reception Only valid in cases where the designated number reception refusal setting FAX is refused 0 Do not refuse reception of designated numbers invalid 2 TSI judgment setting no sig...

Страница 54: ...lag 0 3 Not used 0 4 Ring detection signal select Set which signal is monitored and processed when detecting CI signals 0 Ring detection circuit 1 Silicon DAA RGDT signal 0 Ring detection circuit 5 V 17 carrier frequency Set during configuration of the V 17 mode Carrier frequency in the V 17 mode 0 1800Hz 1 1700Hz 0 1800Hz SW82 1 8 Initial value 00000100 North America China Thailand Malaysia Phili...

Страница 55: ...easured in line probing The characteristic is such that the larger the value is the lower the symbol rate is set Setting can be made over the range of 0 6dBm to 15 6dBm in 1dBm increments by binary inputting see below 1 6dBm 2 6dBm 3 14 5dBm 4dBm 1dBm increments 13 5dBm 14 6dBm 15 6dBm 1 0 0dBm 0 0 0 90 1 4 Primary channel communication speed selection threshold value This sets the standard for de...

Страница 56: ...an CE standard In cases where the machine cannot shift from CFR or MCF to high speed signals image signals due to lightning interference this extends the MPS waiting time Usually communication error occurs at 4 seconds according to the T2 timer 00 0 second 01 20 seconds 10 30 seconds 11 40 seconds 0 0 second North America New Zealand China Singapore Indonesia Thailand Malaysia India Philippine Hon...

Страница 57: ...0 0 1 0 0 0 116 1 8 Not used 0 0 1 0 0 0 0 0 SW109 1 8 Initial value 10101010 North America Australia Sweden Finland Norway Denmark Netherlands Italy Switcherland Austria New Zealand China Singapore Indonesia Thailand Malaysia India Philippine Hong Kong Taiwan Middle East Slovakia Other3 South Africa Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 10001010 U K France Germany Rusia S...

Страница 58: ...0110010 India 01100010 Singapore South Africa 01010010 Indonesia Thailand Malaysia Philippine 10000010 U K France Germany Sweden Finland Norway Denmark Netherlands Italy Switcherland Austria New Zealand Slovakia Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 10100010 Australia Rusia SW119 1 8 Initial value 00001011 North America Indonesia Philippine Taiwan Middle East Other3 Rusia ...

Страница 59: ...e 10000111 North America Australia U K France Germany Sweden Finland Norway Denmark Netherlands Italy Switcherland Austria New Zealand Singapore Indonesia Malaysia India Philippine Taiwan Middle East Slovakia Other3 Rusia South Africa Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 10100101 China Thailand Hong Kong SW126 1 8 Initial value 00000000 North America New Zealand China Ind...

Страница 60: ... Indonesia Thailand Malaysia India Philippine Hong Kong Taiwan Middle East Other3 00000010 Italy Austria Rusia 00010010 U K France Germany Finland Norway Denmark Netherlands Switcherland Slovakia South Africa Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland 00110010 Sweden 01000000 New Zealand SW131 1 8 Initial value 00100011 North America Australia New Zealand China Singapore Indone...

Страница 61: ...rth America Australia New Zealand China Singapore Indonesia Thailand Malaysia India Philippine Hong Kong Taiwan Middle East Rusia South Africa 00010000 U K France Germany Sweden Finland Norway Denmark Netherlands Italy Switcherland Austria Slovakia Other3 Spain Portuguese Luxemburg Belgium Czech Hungary Greece Poland SW141 1 8 Initial value 10000000 North America Australia Norway Switcherland Aust...

Страница 62: ...ode 4 Processing at times of mail reception when the Content X CIAJWNETFAX field is not yet received Setting to determine whether or not to print the mail text in cases where there is no CONtent X CIAJWNETFAX in the mail field when mail is received by Internet FAX 0 Do not print mail letters 1 Print the main text of mails Exclude confirmed sent mails 0 Do not print Internet FAX reception setting 5...

Страница 63: ...communication 0 Treat as 1 successive communication 1 Treat each communication as 1 0 Treat each communication as 1 3 Valid Invalid setting of Internet FAX A4 8 5 x 11 threshold When printing received Internet FAX data with A4 and 8 5 x 11 paper in the tray this setting determines whether to make threshold values in paper selection valid or invalid 0 Valid 1 Invalid Setting of FAX received data is...

Страница 64: ...b valid or invalid 0 Permitted 1 Prohibited 0 Permitted WEB Control setting 5 Prohibition of forwarding permission revision Setting to determine whether to make the Prohibition of forwarding permission revision function that can be registered from the Web valid or invalid 0 Permitted 1 Prohibited 0 Permitted WEB Control setting 6 Received data print conditions in user transfer Setting to determine...

Страница 65: ...k the FAX unit PWB ROM Trouble content EEPROM access error read write Section FAX Case 1 Cause EEPROM trouble Check and remedy Check that no trouble occurs after replacement of EEPROM Execute the memory check of SIM66 3 to insure that EEPROM can be accessed Case 2 Cause FAX PWB EEPROM access circuit trouble Check and remedy Replace the PWB In this case not need to execute the simulation Trouble co...

Страница 66: ...TC 3 FTT EOP 4 MCF EOM 5 PIP PIN MPS 6 RTN RTP PRI Q 7 No signal DCN DCN 8 PPR PPS EOP 9 PPS EOM 10 PPS MPS PPS NULL 11 RNR RR 12 CTR CTC 13 ERR EOR Q 14 PPS PRI Q 16 Abnormal signal Abnormal signal 17 NSF DIS SID SUB NSS DCS 18 CFR PWD SEP NSC DTC 19 FTT PPS EOP 20 MCF PPS EOM 21 PIP PIN PPS MPS PPS NULL 22 RTN RTP PRI Q 23 No signal DCN DCN 24 PPR 25 RNR RR 26 CTR CTC 27 ERR EOR Q 28 PPS PRI Q 2...

Страница 67: ...OVER In PC FAX reservation the number of remote parties is exceeded Send 71 NG71 XXXX 1 In PC FAX reservation data sent from PC includes some errors Send 72 NG72 XXXX 1 In department management setting on the machine side In reservation from PC FAX or PC Internet FAX a department number which is not registered on the machine side is specified Send In reservation from PC FAX or PC Internet FAX the ...

Страница 68: ...flows during writing data into the memory device when Scan to USB is executed 98 NG98 XXXX 1 The copy inhibit pattern is detected when scanning a document 99 NG99 XXXX 1 A document which is inhibited to be copied such as a banknote is scanned Report code Communication result Display in the column of result Content of communication interruption Report code 2 Content of communication interruption Se...

Страница 69: ...cument filed data data cannot be stored in HD after conversion of resolution for resend Resend 70 E mail header acquisition error E mail receive 71 Time out occurs during e mail receive E mail receive 72 Receive reject occurs during e mail receive E mail receive 73 Network communication cannot be made due to port disable Network send 74 An authentication of the POP server is failed when POP before...

Страница 70: ...ox Name Sub Address Print PIN Relay Broadcast Box Name Sub Address Recipients X Modify Delete Polling Memory Confidential Relay Broadcast Custom Index X User 1 X User 2 X User 3 X User 4 X User 5 X User 6 Fax Data Receive Forward Receive Mode Auto Reception Fax Data Forward Item Factory default setting Operation Settings Keys Touch Sound X Keys Touch Sound Medium X Keys Touch Sound at Initial Poin...

Страница 71: ...e Sound Time Setting 3 sec Item Factory default setting Fax Send Complete Signal Volume Medium Tone Pattern 3 Transmission Complete Sound Time Setting 3 sec Fax Communication Error Signal Volume Medium Tone Pattern 3 Transmission Complete Sound Time Setting Every 0 3 seconds Remote Reception Number Setting 5 Original Print on Transaction Report Print at Error Transaction Report Print Select Settin...

Страница 72: ...nding Activity Report Internet Fax X Image Sending Activity Report Fax Anti Junk Fax Number List Anti Junk Mail Domain Name List 2 Forward Table List 2 Web Setting List Metadata Set List Enable Disable Settings Image Send Settings X Disable Switching of Display Order Disable X Disable Scan Function Disable PC Scan Disable USB Memory Scan Disable X Settings to Disable the Registration of Destinatio...

Страница 73: ...fault setting Inside scanned image The transmitted image length will be length of sender information length of original image When the fax is printed by the receiving machine it may be reduced or divided onto two pages The sender information is printed inside the original image and thus the transmitted image length is the length of the original Note that the sender information will overlap part of...

Страница 74: ...MN195006E EXHKD SON1 SON2 PIC Microcomputer PIC16F627A CID RGDT CI detection CPU SH7706 UART Download MFP IF connector FAX_TXD D FAX_TXD D FAX_RXD D FAX_RXD D FAX_CTS D FAX_RTS D RES_MFP FFVPP MSW_MON WUP_FAX PLED RES_FAX CNCT_FAX 12V 5V 3 3V 5V2 16bit 32bit 32bit 16bit 16bit 32bit 5V2 5V2 E2PROM CAT24W02 I2C JTAG Debug connector JTAG UART Debug connector Operation in 1W 7W Energy saving mode FAX_...

Страница 75: ...12 D GND 9 FAX_TXD CS _P 10 n RES_FAX 7 FAX_TXD D _P 8 n MSW_MON 5 FAX_TXD D _N 6 n CNCT_FAX 3 3 3V 4 3 3V 1 D GND 2 D GND 1 12V 2 P GND 3 12V 4 P GND 5 150VON 6 CION 7 48VON 8 HS1 9 HS2 10 CI 11 EXHS 12 SON1 13 SON2 14 ECON 15 MRON 16 TELID 17 NC 18 NC 19 NC 20 NC 21 GND 22 3 3V 23 GND 24 5VS 25 GND 26 SI3_RES 27 SPK 28 ATXD 29 ARXD 30 ABITCLK 31 ASPCLK 32 RGDT 33 MDM_CLK 34 AFE_RES 35 BBITCLK 36...

Страница 76: ...Memo ...

Страница 77: ...Memo ...

Страница 78: ...bout 220 C which is about 40 C higher than that of conventional lead solder and its soldering capacity is inferior to conventional one it is apt to keep the soldering iron in contact with the PWB for longer time This may cause land separation or may exceed the heat resistive temperature of components Use enough care to separate the soldering iron from the PWB when completion of soldering is confir...

Страница 79: ...sfara vid felaktigt batteribyte Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera använt batteri enligt fabrikantens instruktion German Achtung Explosionsgefahr bei Verwendung inkorrekter Batterien Als Ersatzbatterien dürfen nur Batterien vom gleichen Typ oder vom Hersteller empfohlene Batterien verwendet werden Entsorgung der gebrauchten Batterien nu...

Страница 80: ... 2000 Windows XP Windows 2000 Server Windows Server 2003 and Internet Explorer are trademarks or copyrights of Microsoft Corporation in the U S A and other countries IBM and PC AT are trademarks of International Business Machines Corporation Acrobat Reader Copyright 1987 2002 Adobe Systems Incorporated All rights reserved Adobe the Adobe logo Acrobat and the Acrobat logo are trademarks of Adobe Sy...

Отзывы: