MX-FXX1 SIMULATIONS, FAX SOFTWARE SWITCH 5 – 34
48
1-4
V.34 Symbol Rate
Mask (when receiving)
This sets the symbol rate when receiving in the V.34 mode.
"0000": 2400
"0001": 2400
"0010": 2800/2400
"0011": 3000/2800/2400
"0100": 3200/3000/2800/2400
"0101": 3429/3200/3000/2800/2400
When set at a value other than those shown above, the initial value of
"0101" is activated.
0
3429/3200/3000/2800/
2400
1
0
1
5-8
Not used
0
1
0
0
49
1-5
Not used
0
1
0
1
0
6
PIN code
correspondence
Setting to determine whether or not to limit FAX dial number display to
16 digits. When this is set to "1: Correspond," FAX number display
based on the resend key and the other party’s number on the job status
completion screen are displayed from the start to the 16th digit. When
this SW is set as valid, it is also reflected in report contents.
"0": Do not correspond
"1": Correspond
FAX address display limit (displayed up to the 16th digit from the front)
0
Do not correspond
7-8
Dial call waiting time
This sets the waiting time from the end of line connection to the start of
dial call at times of automatic dial calling.
"00": 3.5 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
This only functions when dial tone detection is OFF.
0
3.5 seconds (North
America/Australia/France/
Germany/Sweden/
Switcherland/Austria/
China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle
East/Other3/Rusia)
0
0
4 seconds (U.K./Finland/
Norway/Denmark/
Netherlands/Italy/New
Zealand/Slovakia/South
Africa/Spain/Portuguese/
Luxemburg/Belgium/
Czech/Hungary/Greece/
Poland)
1
50
1-7
Not used
1
0
1
0
0
1
1
8
Dial tone ON detection
time (during
continuous detection)
This sets the waiting time from the end of line connection to the start of
dial call at times of automatic dial calling.
"00": 3.5 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
This only functions when dial tone detection is OFF.
0
1.5 seconds
51
1-4
Time for prohibition of
waiting at both speeds
after sending CFR/
MCF
Setting to determine how many seconds to prohibit waiting at both
speeds (slow and fast) after sending the CFR signal from the machine.
Binary inputting 200ms intervals
Setting range 200 - 2800ms
1600ms when "0000" is set.
0ms when "1111" is set.
0
1600ms
0
0
0
5-6
Not used
0
0
7-8
V.8 mode ANSam
signal sending time
This sets the ANSam signal sending time when the ANSam signal is
sent in the V.8 mode.
"00": 3 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
0
4 seconds
1
SW
No.
Bit
No.
Item
SW selection and function
Initial value
System
settings