24
If you think the unit is not working poperly, check the following points before calling for
service.
Symptoms
Unit does not operate
when power ON/OFF but-
ton is pressed.
Dehumidification capacity
has dropped.
Humidity does not reduce
in any of the operating
mode.
Displayed humidity is
different from actual humi-
dity.
Operation is noisy.
Water is leaking.
The unit repeats operating
and stopping.
The “High-temperature”
indicator on the liquid-
crystal display blinks and
the operation stops.
Before Calling for Service
TINSEA020FBRZ
Check Points
●
Has it been 3 minutes or more after inserting power plug? (
20)
●
Is the water tank installed properly?
●
Is the water tank full?
●
Is the unit plugged in properly?
●
Has there been a power failure?
●
Does the time indication part of TIMER on the liquid-crystal display express
alternately the figure “ ” • (full stop). If so, contact the shop you purchased
after pulling out the power plug.
●
Has the usable period (about 6 months) of the filter passed or is the filter clogged?
●
Is the front filter clogged?
●
Is the air outlet or intake obstructed?
●
Is the temperature and humidity of your room too low?
●
Is the operation mode set to air purification?
●
Is your room too big?
●
Are the windows or doors opened and closed frequently?
●
Are there any devices that produce water vapor in the same area, such as a
kerosene heater?
●
Is the operation mode set to air purification?
●
Displayed humidity is not accurate when the water tank is full or when the unit
is just turned on.
●
Displayed humidity indicates the ambient humidity around the unit. This may
be different to the humidity in a different location in the same room.
●
Is the dehumidifier properly installed on a stable base?
●
Is the floor flat?
●
When the unit starts its operation at a low temperature, the sound might in-
crease for several seconds. (The time depends on the temperature condition.)
●
Has the unit been knocked over, or has it been tilted or dropped?
●
Is the pipe connection or hose connection for continuous drainage in place?
(
14)
●
Is humidity automatically controlled by AUTO DRY mode or ROOM DRY opera-
tion? (
12)
●
If the “ High-temperature “ still continues to appear after checking it again
based on page 5 “Cautions for use”, contact the shop you purchased or your
dealer after pulling out power plug.