GB-13
ENGLISH
NOTE IN USING THE UNIT AS A
MULTI-SYSTEM
With a multi system air conditioner, multiple in-
door units can connect to one outdoor unit.
With a multi system air conditioner, you can not
operate different indoor units in different mode.
• If one unit is operating in COOL (or DRY)
mode, the other units are to be operated in
the same mode. The mode of the indoor unit
which operates
fi
rst is given priority. The in-
door unit turned on later in different mode can
not start operation. It starts to beep and the
OPERATION lamp and TIMER lamp starts to
blink. In this case, set all the indoor units to
the same operation mode.
• COOL mode and DRY mode can be set at the
same time.
NOTES ON OPERATION
OPERATING CONDITION
Cooling
Indoor temperature
Outdoor temperature
Single
Multi
upper limit
32°C
46°C
43°C
lower limit
21°C
-10°C
21°C
Heating
Indoor temperature
Outdoor temperature
upper limit
27°C
24°C
lower limit
-
-15°C
• The built-in protective device may prevent the
unit from operating when used at higher tem-
perature than this range.
• Condensation may form on the air outlet if the
unit operates continuously in the COOL or
DRY mode when humidity is over 80 %.
NOTE ON HEATING OPERATION
DEFROSTING FUNCTION
• When frost forms on the outdoor unit during
heating operation, the unit operate automatic
defrosting for about 5 to 10 minutes to remove
the frost. During defrosting, the indoor and out-
door fans stop operating.
HEATING EFFICIENCY
• The unit employs a heat pump that draws
heat from the outside air and releases it into
the room. The outside temperature therefore
greatly affects the heating ef
fi
ciency.
• If the heating ef
fi
ciency is reduced due to low
outside temperature, use an additional heater.
• It takes time to warm up and heat the entire
room because of the forced air circulation sys-
tem.
WHEN POWER FAILURE OCCURS
• This air conditioner has a memory function to
store settings when a power failure occurs.
After power recovery, the unit will automati-
cally re-start in the same settings which were
active before the power failure, except for
timer and FULL POWER settings.
• If a power failure occurs while the timer is set,
the timer setting will be cancelled and will not
be retrieved even after the power is restored.
RR_OM_10_lang.indb GB-13
RR_OM_10_lang.indb GB-13
2014-02-21 08:53:34
2014-02-21 08:53:34
Содержание AY-XPC12RR
Страница 162: ......
Страница 164: ...Printed in China TINSEA847JBRZ 14C CN 1 ...