AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 34
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Press [CUSTOM SETTINGS] key.
4) Press [START] key.
Operation/Procedure
When bit =1, correction is made.
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
*1: Only when this value is 0, control is made with the actual mea-
surement value of the process thermistor (temperature/humid-
ity). When it is not 0, control is made with the forcible setting
value.
43
43-1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each
operation mode.
Section
Fixing (Fusing)
Item
Operation
Item
Default
1
INSIDE NORMAL
Heater inside/normal
190
2
OUTSIDE NORMAL
Heater outside/normal
190
3
INSIDE PREHEAT
Heater inside/preheat
150
4
OUTSIDE PREHEAT
Heater outside/preheat
150
Press [START] key.
Press [CUSTOM SETTINGS] key.
44
44-1
Purpose
Setting
Function
(Purpose)
Used to set enable/disable of correction
operations in the image forming (process) section.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Operation
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
Vg4
Vb4
Ld4
Vbr
Vg3
Vb3
Ld3
Vb1
Vb2
Ld2
Vg2
Ld1
Vg1
SIMULATION 41-3
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200 PD2[128]: 200
PD3[128]: 50 PD4[128]: 52
PD5[128]: 51 PD6[128]: 50
PD7[128]: 52
SIMULATION 43-1
1
FUSER TEMPERATURE SET. SELECT 1-4, AND PRESS START.
1. INSIDE NORMAL
190
2. OUTSIDE NORMAL
190
3. INSIDE PREHEAT
150
4. OUTSIDE PREHEAT
150
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
190
44-4
Purpose
Setup
Function
(Purpose)
Used to set the target image (reference) density
level in the developing bias voltage correction.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Data
Item
1
TEMP. AREA *1
Process environment temperature
forcible setting value
(0 - 13 /normal: 0)
2
HUMIDITY AREA *1
Process environment humidity
forcible setting value
(0 - 14 /normal: 0)
3
S_WT
Vb rising correction standby time
(0 - 180 sec/default: 90)
4
Vb1
Vb correction amount (first rotation)
(0 - 150V/default: 50)
5
Vb2
Vb correction amount (second
rotation) (0-50V/default: 15)
Press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 44-1
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-255
AND PRESS START.
BIT0:Vg1, BIT1:Ld1, BIT2:Vg2, BIT3:Ld2
BIT4:Vb1, Vb2
BIT5:Vg3, Vb3, Ld3
BIT6:Vbr
BIT7:Vg4, Vb4, Ld4
111
SIMULATION 44-4
3
PROCESS CONTROL VALUE SETTING. SELECT 1-5 AND PRESS
START.
1.TEMP. AREA
0
2.HUMIDITY AREA
0
3.S_WT
100
4.Vb1
50
5.Vb2
50
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. INPUT VALUE, AND PRESS
START.
3.S_WT
101
Содержание AR-M351N
Страница 272: ...Memo ...
Страница 273: ...Memo ...